Native valve disease in patients with non-valvular atrial fibrillation on warfarin or rivaroxaban
Conclusions We found that patients with AF and AS on oral anticoagulants may have distinctly different efficacy and safety outcomes than patients with MR or AR or no SVD. Trial registration number NCT00403767; Post-results.
Source: Heart - June 9, 2016 Category: Cardiology Authors: Breithardt, G., Baumgartner, H., Berkowitz, S. D., Hellkamp, A. S., Piccini, J. P., Lokhnygina, Y., Halperin, J. L., Singer, D. E., Hankey, G. J., Hacke, W., Becker, R. C., Nessel, C. C., Mahaffey, K. W., Califf, R. M., Fox, K. A. A., Patel, M. R., for th Tags: Open access, Drugs: cardiovascular system, Interventional cardiology, Aortic valve disease, Mitral valve disease Valvular heart disease Source Type: research

Japanese Multicenter Outcomes With the HeartMate II Left Ventricular Assist Device in Patients With Small Body Surface Area.
CONCLUSIONS: Results for HMII LVAD as BTT in the post-approval era showed excellent survival and functional capacity improvement. Of particular interest to the Japanese patient population are the excellent results in patients with small BSA. PMID: 27373233 [PubMed - as supplied by publisher]
Source: Circulation Journal - July 3, 2016 Category: Cardiology Authors: Ono M, Sawa Y, Nakatani T, Tominaga R, Matsui Y, Yamazaki K, Saiki Y, Niinami H, Matsumiya G, Arai H, Japanese HeartMate II investigators Tags: Circ J Source Type: research

#HeartWarrior: Maddy Reyes
Maddy Reyes is a 12-year-old Heart Warrior participating in the 2016 Puget Sound Heart and Stroke Walk. She is also a social media ambassador, @MaddyGoCheer. I have a different heart than most kids. When I was born I was diagnosed with a heart condition called Tetralogy of Fallot. The doctors and surgeons were watching my heart very closely until I was four months old. When I was four months old my doctor told my parents that I would have to get open heart surgery to keep my heart safe. The surgeons fixed a hole in my heart and made my pulmonary artery bigger. My doctor is now watching my heart closely to see when ...
Source: Healthy Living - The Huffington Post - August 22, 2016 Category: Consumer Health News Source Type: news

Long-Term Exposure to Ambient Fine Particulate Matter and Renal Function in Older Men: The Veterans Administration Normative Aging Study
Conclusions: In this longitudinal sample of older men, the findings supported the hypothesis that long-term PM2.5 exposure negatively affects renal function and increases renal function decline. Citation: Mehta AJ, Zanobetti A, Bind MC, Kloog I, Koutrakis P, Sparrow D, Vokonas PS, Schwartz JD. 2016. Long-term exposure to ambient fine particulate matter and renal function in older men: the VA Normative Aging Study. Environ Health Perspect 124:1353–1360; http://dx.doi.org/10.1289/ehp.1510269 Address correspondence to A.J. Mehta, Department of Environmental Health, Harvard T.H. Chan School of Public Health, Landmark Ce...
Source: EHP Research - September 1, 2016 Category: Environmental Health Authors: Web Admin Tags: Research Article September 2016 Source Type: research

ApoA-1 Mimetic Peptides Promoting Lipid Efflux from Cells for Treatment of Vascular Disorders
This invention involves ApoA-1 mimetic peptides with multiple amphipathic alpha-helical domains that promote lipid efflux from cells and are useful in the treatment and prevention of dyslipidemic, inflammatory and vascular disorders. IND-enabling studies for one of the peptides, named Fx-5A, are completed in preparation for an IND filing at the FDA, to be followed by a Phase I clinical trial planned for 2017. Disorders amenable to treatment with the peptides include hyperlipidemia, hyperlipoproteinemia, hypercholesterolemia, HDL deficiency, hypertriglyceridemia, apoA-I deficiency, acute coronary syndrome, angina pectoris, ...
Source: NIH OTT Licensing Opportunities - February 1, 2008 Category: Research Authors: ajoyprabhu3 Source Type: research

AliveCor raises $30m, launches Kardia Pro platform in U.S.
AliveCor said today that it landed $30 million in a series D funding round and that it released its artificial intelligence-enabled Kardia Pro platform in the U.S. The company’s platform enables doctors to remotely monitor their patients for early signs of atrial fibrillation, a common cardiac arrhythmia. “Heart disease is the No. 1 cause of death in the United States, claiming more lives than all forms of cancer combined. To manage heart disease and stroke risk, leading cardiologists want to see more than just ECGs from their patients,” CEO Vic Gundotra said in prepared remarks. “Kardia Pro tracks important meas...
Source: Mass Device - March 16, 2017 Category: Medical Equipment Authors: Sarah Faulkner Tags: Cardiovascular Funding Roundup Patient Monitoring Wall Street Beat AliveCor Source Type: news

MassDevice.com +5 | The top 5 medtech stories for May 12, 2017
Say hello to MassDevice +5, a bite-sized view of the top five medtech stories of the day. This feature of MassDevice.com’s coverage highlights our 5 biggest and most influential stories from the day’s news to make sure you’re up to date on the headlines that continue to shape the medical device industry. Get this in your inbox everyday by subscribing to our newsletters.   5. Xtant Medical amends Orbimed credit line to $15m, taps restructuring advisors Xtant Medical said today that it amended its senior credit line with OrbiMed Advisors, saying it plans to use the $15 million facility to pay off the ...
Source: Mass Device - May 12, 2017 Category: Medical Devices Authors: MassDevice Tags: News Well Plus 5 Source Type: news

Outcomes of Cardiac Pacing in Adult Patients After a Fontan Operation
Conclusions More than one-third of adult Fontan patients referred to Mayo Clinic had pacemaker implantation. Epicardial leads were associated with high rate of pacemaker reinterventions but similar DRC rates in comparison to endocardial leads.
Source: American Heart Journal - August 26, 2017 Category: Cardiology Source Type: research

Heart Transplant Outcomes in Patients With Pretransplant Diabetes Mellitus.
CONCLUSIONS: Heart transplant recipients with pretransplant diabetes fared just as well as patients without pretransplant diabetes in 7 of the 8 outcomes examined, except for the number of days hospitalized during the first 3 years after heart transplant. This study provides clinically important new information on the greater hospitalization time and the reasons for hospitalization during the first 3 years after heart transplant in patients with pretransplant diabetes. PMID: 29092871 [PubMed - in process]
Source: American Journal of Critical Care - November 1, 2017 Category: Nursing Authors: Jalowiec A, Grady KL, White-Williams C Tags: Am J Crit Care Source Type: research

Incremental Value of Deformation Imaging  and Hemodynamics Following Heart Transplantation
Conclusions RAP and LVGLS at the first annual evaluation provide complementary prognostic information in predicting 5-year outcome after HT. Graphical abstract
Source: JACC: Heart Failure - November 28, 2017 Category: Cardiology Source Type: research

Prognostic value of hemodynamics following treatment initiation in pulmonary arterial hypertension
Conclusions: Stroke volume index and right atrial pressure at first follow-up catheterization were the best hemodynamic predictors of death or transplantation. These variables should be further validated as treatment targets in a prospective study.
Source: European Respiratory Journal - December 6, 2017 Category: Respiratory Medicine Authors: Weatherald, J., Adir, Y., Boucly, A., Savale, L., Simonneau, G., Montani, D., Jaïs, X., Humbert, M., Chemla, D., Sitbon, O., Herve, P. Tags: Pulmonary Circulation and Pulmonary Vascular Disease Source Type: research

4D Flow MRI in 3D Printed Models of Aorta Grafted With a Ventricular Assist Device Allows Detailed Embolic Trajectory Analysis
Embolic stroke remains an important source of morbidity and mortality in heart failure patients treated with Ventricular Assist Devices (VADs). Decreasing the probability of cranial versus descending aortic embolic trajectory by optimizing the VAD outflow graft position and terminal curvature angle could reduce embolic stroke risk. The goal of this study is to investigate particle trajectories released by a VAD into the aorta, and the effect changes in outflow graft insertion site and terminal curve have on those trajectories.
Source: The Journal of Heart and Lung Transplantation - March 31, 2018 Category: Transplant Surgery Authors: O. Amili, F. Coletti, R. MacIver Source Type: research

Individualized Biventricular Epicardial Augmentation Technology in a Drug-Induced Porcine Failing Heart Model
This study investigated an individualized biventricular epicardial augmentation technology in a drug-induced porcine failing heart model. A total of 11 pigs were used, for the assessment of hemodynamics and cardiac function under various conditions of support pressures and support durations (n = 4), to assess device positioning and function by in vivo computer tomographic imaging (n = 3) and to investigate a minimally invasive implantation on the beating heart (n = 4). Support pressures of 20–80 mm Hg gradually augmented cardiac function parameters in this animal model as indicated by increased left ventricular stroke ...
Source: ASAIO Journal - June 29, 2018 Category: Medical Devices Tags: Adult Circulatory Support Source Type: research

Invasive Hemodynamics and Rejection Rates in Patients With Cardiac Sarcoidosis After Heart Transplantation
ConclusionsPatients with CS have similar post-transplant hemodynamics as patients without CS, without evidence of right ventricular dysfunction or pulmonary hypertension. Neither significant rejection nor recurrence of sarcoid in the allograft was observed in this cohort of patients with CS. Survival is similar between patients with CS and those without CS. Heart transplant is a viable strategy in selected patients with CS with excellent outcomes.RésuméIntroductionLa transplantation cardiaque orthotopique (TCO) est de plus en plus utilisée lors d’insuffisance cardiaque terminale liée à une sarcoïdose cardiaque (SC)...
Source: Canadian Journal of Cardiology - July 24, 2018 Category: Cardiology Source Type: research

Left ventricular assist device exchange for the treatment of HeartMate II pump thrombosis.
Conclusions: It is generally feasible to treat pump thrombosis via LVAD exchange. Yet, the exchange procedure is not without risk and the risk of re-thrombosis (34%), stroke (29%), postoperative dialysis (29%) and perioperative complications remains high. PMID: 30034845 [PubMed]
Source: Journal of Thoracic Disease - July 25, 2018 Category: Respiratory Medicine Tags: J Thorac Dis Source Type: research