Filtered By:
Procedure: Lung Transplant

This page shows you your search results in order of date. This is page number 14.

Order by Relevance | Date

Total 372 results found since Jan 2013.

The Society of Thoracic Surgeons Intermacs Database Annual Report: Evolving Indications, Outcomes, and Scientific Partnerships
ConclusionsWith the evolution of MCS, patient phenotype and outcomes are also changing over time. CF LVAD support is increasingly being used in the less ill patient phenotype and more patients are supported for destination therapy. Mean survival is now approaching 5 years, but adverse events, especially neurologic events, continue to have a detrimental impact on the success of CF LVAD support.
Source: The Annals of Thoracic Surgery - January 26, 2019 Category: Cardiovascular & Thoracic Surgery Source Type: research

Korean JLK Inspection launches AI-powered imaging diag system
Korean JLK Inspection said yesterday that it launched its AIHub artificial intelligence-powered medical image diagnostics platform. The newly launched AIHub system is designed to analyze images from a number of different imaging modalities, including magnetic resonance imaging, computed tomography, X-ray and mammography, the Seoul-based company said. JLK Inspection claims the system can detect and monitor for more than 30 medical conditions in 14 regions of the body. The company added that the system is focused on brain diseases and conditions including ischemic stroke, hemorrhagic stroke, brain aneurysm and Alzheimer̵...
Source: Mass Device - December 27, 2018 Category: Medical Devices Authors: Fink Densford Tags: Diagnostics Imaging Software / IT jlkinspection Source Type: news

Prognostic implications of serial outpatient blood pressure measurements in patients with a left ventricular assist device
Elevated blood pressure (BP) has been linked to adverse events during left ventricular assist device support. We aimed to investigate the association between outpatient BP and stroke or suspected pump thrombosis among HeartMate II (HMII) recipients.
Source: The Journal of Heart and Lung Transplantation - November 15, 2018 Category: Transplant Surgery Authors: Alberto Pinsino, Francesco Castagna, Amelia M Zuver, Eugene A Royzman, Mojdeh Nasiri, Eric J St öhr, Barbara Cagliostro, Barry McDonnell, John R Cockcroft, A Reshad Garan, Veli K Topkara, P Christian Schulze, Koji Takeda, Hiroo Takayama, Yoshifumi Naka, Tags: Original Clinical Science Source Type: research

Prognostic implications of serial outpatient blood pressure measurements in patients with an axial continuous-flow left ventricular assist device
In this study we investigated the association between outpatient BP and stroke or suspected pump thrombosis among HeartMate II (HMII) recipients.
Source: The Journal of Heart and Lung Transplantation - November 15, 2018 Category: Transplant Surgery Authors: Alberto Pinsino, Francesco Castagna, Amelia M. Zuver, Eugene A. Royzman, Mojdeh Nasiri, Eric J. St öhr, Barbara Cagliostro, Barry McDonnell, John R. Cockcroft, A. Reshad Garan, Veli K. Topkara, P. Christian Schulze, Koji Takeda, Hiroo Takayama, Yoshifumi Tags: ORIGINAL CLINICAL SCIENCE Source Type: research

Unusual Techniques for Preserving Surgical and Oncologic Safety in Hepatectomy of Advanced Adrenal Malignancy with Vena Cava and Liver Invasion
We report herein three cases of major hepatectomy with IVC invasion and discuss several surgical tips.Patients and MethodsFrom March 2011 to February 2014, we retrospectively reviewed three cases of adrenal malignancy with liver and IVC invasion. Based on the severity of the malignant tumor, each case illustrates a different method to address surgical complications and maintain oncologic safety. Case 1: A 34-year-old woman was diagnosed with adrenocortical tumor during medical examination. Tumor invaded the right lobe of the liver and very close to the IVC. Fortunately, there was little thrombosis inside the IVC; we perfor...
Source: Annals of Surgical Oncology - October 1, 2018 Category: Cancer & Oncology Source Type: research

The value of Stanford integrated psychosocial assessment for transplantation (SIPAT) in prediction of clinical outcomes following left ventricular assist device (LVAD) implantation
ConclusionIn this single-center retrospective study, SIPAT did not predict cumulative re-admissions. Further study is required to validate SIPAT before clinical implementation.
Source: Heart and Lung: The Journal of Acute and Critical Care - September 16, 2018 Category: Respiratory Medicine Source Type: research

Unusual Techniques for Preserving Surgical and Oncologic Safety in Hepatectomy of Advanced Adrenal Malignancy with Vena Cava and Liver Invasion
We report herein three cases of major hepatectomy with IVC invasion and discuss several surgical tips.Patients and MethodsFrom March 2011 to February 2014, we retrospectively reviewed three cases of adrenal malignancy with liver and IVC invasion. Based on the severity of the malignant tumor, each case illustrates a different method to address surgical complications and maintain oncologic safety. Case 1: A 34-year-old woman was diagnosed with adrenocortical tumor during medical examination. Tumor invaded the right lobe of the liver and very close to the IVC. Fortunately, there was little thrombosis inside the IVC; we perfor...
Source: Annals of Surgical Oncology - September 6, 2018 Category: Cancer & Oncology Source Type: research

A lung transplant gave her hope for a longer life; now her family prays for 'another miracle'
Claire Wineland, who has cystic fibrosis, needed a double-lung transplant to save her life. But she had a stroke and is now in a medically induced coma.
Source: CNN.com - Health - August 29, 2018 Category: Consumer Health News Source Type: news

A Tale of the Twist in the Outflow Graft: An Analysis from the MOMENTUM 3 Trial
Heralded as a significant step forward in the evolution of left ventricular assist systems (LVAS), the HeartMate 3 device (Abbott, Abbott Park, Il, USA) has demonstrated improved outcomes by averting de-novo intra-pump thrombosis leading to pump related malfunction, and in reducing the incidence of stroke events when compared with the axial flow HeartMate II LVAS.1,2,3,4 Moreover, the HeartMate 3 LVAS experience has reduced the vexing incidence of hemocompatibility related adverse outcomes.5,6,7 On the heels of these advances, intriguing reports began to surface of a twist within the outflow graft that caused disruption in...
Source: The Journal of Heart and Lung Transplantation - August 24, 2018 Category: Transplant Surgery Authors: Mandeep R. Mehra, Christopher Salerno, Yoshifumi Naka, Nir Uriel, Joseph C. Cleveland, Douglas Horstmanshof, Daniel J. Goldstein, for the MOMENTUM 3 Investigators Tags: Editorial Source Type: research

Invasive Hemodynamics and Rejection Rates in Patients With Cardiac Sarcoidosis After Heart Transplantation
ConclusionsPatients with CS have similar post-transplant hemodynamics as patients without CS, without evidence of right ventricular dysfunction or pulmonary hypertension. Neither significant rejection nor recurrence of sarcoid in the allograft was observed in this cohort of patients with CS. Survival is similar between patients with CS and those without CS. Heart transplant is a viable strategy in selected patients with CS with excellent outcomes.RésuméIntroductionLa transplantation cardiaque orthotopique (TCO) est de plus en plus utilisée lors d’insuffisance cardiaque terminale liée à une sarcoïdose cardiaque (SC)...
Source: Canadian Journal of Cardiology - July 24, 2018 Category: Cardiology Source Type: research

Medtronic ’s HVAD System Just Became Less Invasive
Medtronic has gained FDA approval for a less-invasive implant approach of its HVAD System, a left ventricular assist device (LVAD) for advanced heart failure patients. The Dublin-based company picked up the technology when it acquired HeartWare in 2016. The firm said the technology is the only LVAD approved in the U.S. for implant via thoracotomy, a small lateral, surgical incision between the patient's ribs on the left side of the chest. FDA approval for HVAD implantation via thoracotomy is based on data from the LATERAL prospective clinical trial, in which 144 patients, with end-stage heart failure who were eligible for ...
Source: MDDI - July 12, 2018 Category: Medical Devices Authors: Omar Ford Tags: Cardiovascular Business Source Type: news

AI can detect, assess white-matter lesions on CT scans
Researchers from the U.K. have developed an artificial intelligence (AI) algorithm...Read more on AuntMinnie.comRelated Reading: AI can prescreen chest CT studies for pneumothorax AI can help distinguish lung nodules on CT scans AI, radiomics help distinguish lung nodules on CT scans Infervision debuts AI stroke screening software AI predicts dementia years before symptoms occur
Source: AuntMinnie.com Headlines - May 23, 2018 Category: Radiology Source Type: news

First-in-Man Use of the MVAD Axial-Flow Pump: Long Term Outcome
The use of durable continuous-flow mechanical assist devices provides selected heart failure patients with both symptomatic and functional benefits; however, they are not without potential complications. Infection, thrombosis, stroke and GI bleeding are amongst the most commonly reported problems of left ventricular assist device (LVAD) therapy.1 –3 In addition, LVAD peripherals can be bulky and heavy for the patient to carry, causing joint stress, discomfort and reduced quality of life. Device miniaturization is one design trend that has enabled device implantation in patients with a broader range of body sizes, and whe...
Source: The Journal of Heart and Lung Transplantation - April 24, 2018 Category: Transplant Surgery Authors: Marian Urban, Anfrew Woods, Nicola Robinson-Smith, Guy MacGowan, Chandrika Roysam, Stephan Schueler Source Type: research

First-in-man use of the MVAD axial-flow pump: Long-term outcome
The use of durable continuous-flow mechanical assist devices provides selected heart failure patients with both symptomatic and functional benefits; however, they are not without potential complications. Infection, thrombosis, stroke, and gastrointesinal bleeding are among the most commonly reported problems of left ventricular assist device (LVAD) therapy.1 –3 In addition, LVAD peripherals can be bulky and heavy for the patient to carry, causing joint stress, discomfort, and reduced quality of life.
Source: The Journal of Heart and Lung Transplantation - April 24, 2018 Category: Transplant Surgery Authors: Marian Urban, Anfrew Woods, Nicola Robinson-Smith, Guy MacGowan, Chandrika Roysam, Stephan Schueler Tags: Case Anecdotes, Comments and Opinions Source Type: research

First-in-Man Use of the MVAD Axial-Flow Pump: Long Term Outcome
The use of durable continuous-flow mechanical assist devices provides selected heart failure patients with both symptomatic and functional benefits; however, they are not without potential complications. Infection, thrombosis, stroke and GI bleeding are amongst the most commonly reported problems of left ventricular assist device (LVAD) therapy.1 –3 In addition, LVAD peripherals can be bulky and heavy for the patient to carry, causing joint stress, discomfort and reduced quality of life. Device miniaturization is one design trend that has enabled device implantation in patients with a broader range of body sizes, and whe...
Source: The Journal of Heart and Lung Transplantation - April 24, 2018 Category: Transplant Surgery Authors: Marian Urban, Anfrew Woods, Nicola Robinson-Smith, Guy MacGowan, Chandrika Roysam, Stephan Schueler Source Type: research