Descriptive retrospective study analyzing relevant factors related to dental implant failure.
CONCLUSIONS: Analysis of these implants reveals a higher rate of complication in short, tapered, internal connection and narrow-diameter implants. These data can help and encourage clinicians to use the utmost surgical precautions when placing these implants.