Machine perfusion preservation versus static cold storage for deceased donor kidney transplantation.

CONCLUSIONS: HMP is superior to SCS in deceased donor kidney transplantation. This is true for both DBD and DCD kidneys, and remains true in the modern era (studies performed in the last decade). As kidneys from DCD donors have a higher overall DGF rate, fewer perfusions are needed to prevent one episode of DGF (7.26 versus 13.60 in DBD kidneys).Further studies looking solely at the impact of HMP on DGF incidence are not required. Follow-up reports detailing long-term graft survival from participants of the studies already included in this review would be an efficient way to generate further long-term graft survival data.Economic analysis, based on the results of this review, would help cement HMP as the standard preservation method in deceased donor kidney transplantation.RCTs investigating (sub)NMP are required. PMID: 30875082 [PubMed - as supplied by publisher]
Source: Cochrane Database of Systematic Reviews - Category: General Medicine Authors: Tags: Cochrane Database Syst Rev Source Type: research