Ultrasound-driven radical chain reaction and immunoregulation of piezoelectric-based hybrid coating for treating implant infection

Biomaterials. 2024 Mar 14;307:122532. doi: 10.1016/j.biomaterials.2024.122532. Online ahead of print.ABSTRACTThe poor efficiency of US-responsive coatings on implants restricts their practical application. Immunotherapy that stimulates immune cells to enhance their antibacterial activity is expected to synergize with sonodynamic therapy for treating implant infection effectively and safely. Herein, US-responsive hybrid coatings composed of the oxygen-deficient BaTiO3 nanorod arrays and l-arginine (BaTiO3-x/LA) are designed and prepared on titanium implants for sonocatalytic therapy-cooperated immunotherapy to treat Methicillin-resistant Staphylococcus aureus (MRSA) infection. BaTiO3-x/LA can generate more oxidizing reactive oxygen species (ROS, hydroxyl radical (·OH)) and reactive nitrogen species (RNS, peroxynitrite anion (ONOO-)). The construction of nanorod arrays and oxygen defects balances the piezoelectric properties and sonocatalytic capability during US treatment. The generated piezoelectric electric field provides a sufficient driving force to separate electrons and holes, and the oxygen defects attenuate the electron-hole recombination efficiency, consequently increasing the yield of ROS during the US treatment. Moreover, nitric oxide (NO) released by l-arginine reacts with the superoxide radical (·O2-) to produce ONOO-. Since, this radical chain reaction improves the oxidizing ability between bacteria and radicals, the cell membrane (argB, secA2) and DNA (dnaBGXN...
Source: Biomaterials - Category: Materials Science Authors: Source Type: research