Automated oxygen delivery for preterm infants with respiratory dysfunction

CONCLUSIONS: Automated oxygen delivery compared to routine manual oxygen delivery probably increases time in desired SpO2 ranges in preterm infants on respiratory support. However, it is unclear whether this translates into important clinical benefits. The evidence on clinical outcomes such as severe retinopathy of prematurity are of low certainty, with little or no differences between groups. There is insufficient evidence to reach any firm conclusions on the effectiveness of automated oxygen delivery compared to enhanced manual oxygen delivery or CLACfast compared to CLACslow. Future studies should include important short- and long-term clinical outcomes such as mortality, severe ROP, bronchopulmonary dysplasia/chronic lung disease, intraventricular haemorrhage, periventricular leukomalacia, patent ductus arteriosus, necrotising enterocolitis, and long-term neurodevelopmental outcomes. The ideal study design for this evaluation is a parallel-group randomised controlled trial. Studies should clearly describe staffing levels, especially in the manual arm, to enable an assessment of reproducibility according to resources in various settings. The data of the 13 ongoing studies, when made available, may change our conclusions, including the implications for practice and research.PMID:38032241 | PMC:PMC10688253 | DOI:10.1002/14651858.CD013294.pub2
Source: Cochrane Database of Systematic Reviews - Category: General Medicine Authors: Source Type: research