Sildenafil Reduces Risk of Ischemic Stroke and Pump Thrombosis with Ongoing Low Level Hemolysis During Heart Mate II Support
Low level hemolysis after Heart Mate (HM) II implantation, as evident by an elevated discharge lactate dehydrogenase (LDH) level>400 U/L, is linked to subsequent thrombotic events. Free hemoglobin from ongoing hemolysis scavenges nitric oxide (NO) to create a NO deficiency which can augment platelet function. We hypothesized the potentiation of NO signaling during low level hemolysis with a phosphodiesterase-5 inhibitor, sildenafil, may lead to reduced thrombotic events.
Source: The Journal of Heart and Lung Transplantation - March 25, 2017 Category: Transplant Surgery Authors: O. Saeed, S. Rangasamy, A. Luke, S.P. Patel, D.B. Sims, J. Shin, M. Reyes Gil, M.J. Slepian, H.H. Billett, D.J. Goldstein, U.P. Jorde Source Type: research

Impact of Body Mass Index on Outcomes After Left Ventricular Assist Device Placement: Evidence from a Meta-Analysis
To investigate the impact of body mass index (BMI) on mortality, rates of device-related infections and stroke/ transient ischemic attack (TIA) after left ventricular assist device (LVAD) placement.
Source: The Journal of Heart and Lung Transplantation - March 25, 2017 Category: Transplant Surgery Authors: A. Vallakati, S. Emani, W.T. Abraham Source Type: research

Managing Anticoagulation in LVAD Patients: The Harefield Experience
Anticoagulation management in patients with Left Ventricular Assist devices (LVAD) continues to be a challenge. Patients and their clinicians are faced with the daily challenge of needing adequate anticoagulation versus the bleeding risks that are associated with anticoagulation.Warfarin is the recommended oral anticoagulant for all currently available LVAD devices.Warfarin is known to be a difficult medication to manage due to its narrow therapeutic window, and its many interactions .Dlott et al (2014) describe in Circulation the overall time in therapeutic range for patients on warfarin as 53.7%, Time in therapeutic rang...
Source: The Journal of Heart and Lung Transplantation - March 25, 2017 Category: Transplant Surgery Authors: R. Hards, G. Edwards, C. Kavanagh, M. Hedger, A.R. Simon Source Type: research

The Treatment of Patients with Advanced Heart Failure Ineligible for Cardiac Transplantation with the HeartWare Ventricular Assist Device: Results of the ENDURANCE Supplement Trial
The ENDURANCE Trial previously demonstrated non-inferiority of the HeartWare centrifugal flow ventricular assist device system (HVAD) to the control HeartMate II (HMII) axial flow device in 445 end-stage heart failure patients ineligible for heart transplantation. However, the rate of strokes in the HVAD cohort was higher than expected. Analysis of early clinical trial data found that elevated mean arterial blood pressure (MAP) was a highly statistically significant independent risk factor for stroke events.
Source: The Journal of Heart and Lung Transplantation - March 25, 2017 Category: Transplant Surgery Authors: C.A. Milano, J.G. Rogers, A.J. Tatooles, G. Bhat, M.S. Slaughter, E.J. Birks, N.A. Mokadam, C. Mahr, J.S. Miller, V. Jeevanandam, K. Leadley, K.D. Aaronson, F.D. Pagani Source Type: research

Mortality, rehospitalization, and post-transplant complications in gender-mismatched heart transplant recipients
Conclusion Female HT recipients with male donors had worse 3-year outcomes as compared to male-mismatch and no-mismatch groups.
Source: Heart and Lung: The Journal of Acute and Critical Care - May 10, 2017 Category: Respiratory Medicine Source Type: research

DIS-17-0023 The Enduring Health Challenges of Afghan Immigrants and Refugees in Iran: A Systematic Review
This article does not contain any studies with human participants or animals performed by the author. Data Availability All national (MagIran, Science Information Database (SID) and Iranmedex) and international (PubMed, Scopus) databases were searched from November 2010 to November 2016 using keywords both in English and Persian: Afghan immigrants, Afghan refugees, Iran, infectious diseases, tuberculosis, HIV, Hepatitis B and C, non-communicable disease, food security, mental health, barriers, health insurance, access to health service. All related websites and webpages were also searched by Google with the same keywords ...
Source: PLOS Currents Disasters - July 21, 2017 Category: International Medicine & Public Health Authors: nasim Source Type: research

The Enduring Health Challenges of Afghan Immigrants and Refugees in Iran: A Systematic Review
This article does not contain any studies with human participants or animals performed by the author. Data Availability All national (MagIran, Science Information Database (SID) and Iranmedex) and international (PubMed, Scopus) databases were searched from November 2010 to November 2016 using keywords both in English and Persian: Afghan immigrants, Afghan refugees, Iran, infectious diseases, tuberculosis, HIV, Hepatitis B and C, non-communicable disease, food security, mental health, barriers, health insurance, access to health service. All related websites and webpages were also searched by Google with the same keywords ...
Source: PLOS Currents Disasters - July 21, 2017 Category: International Medicine & Public Health Authors: nasim Source Type: research

How Genomic Research is Changing Heart Care
Genomic testing is most frequently associated with cancer testing, but this area of research is beginning to make an impact on cardiovascular care. A recent scientific statement by the American Heart Association shined a spotlight on how the expressed genome can potentially be used to diagnose diseases and predict who will develop diseases such as coronary artery disease (CAD), stroke, heart failure, and arrhythmias. According to the statement, scientists now have the ability to address disease at many levels that were inaccessible during the past century. This includes the genome, transcriptome, epigenome, proteome, metab...
Source: MDDI - October 27, 2017 Category: Medical Devices Authors: Amanda Pedersen Tags: IVD Cardiovascular Source Type: news

The Prognostic Value of Follow-up Hemodynamic Variables After Initial Management in Pulmonary Arterial Hypertension.
Conclusions -SVI and RAP were the hemodynamic variables independently associated with death or lung transplantation at first follow-up RHC after initial PAH treatment. These findings suggest that the SVI could be a more appropriate treatment target than the cardiac index in PAH. PMID: 29070502 [PubMed - as supplied by publisher]
Source: Circulation - October 25, 2017 Category: Cardiology Authors: Weatherald J, Boucly A, Chemla D, Savale L, Peng M, Jevnikar M, Jaïs X, Taniguchi Y, O'Connell C, Parent F, Sattler C, Hervé P, Simonneau G, Montani D, Humbert M, Adir Y, Sitbon O Tags: Circulation Source Type: research

The Impact of Age, Sex, Therapeutic Intent, Race, and Severity of Advanced Heart Failure on Short-term Principal Outcomes in the MOMENTUM 3 Trial
Primary outcomes analysis of the MOMENTUM 3 trial short term cohort demonstrated a higher survival rate free of debilitating stroke and reoperation to replace/remove the device (primary endpoint) in patients receiving the HeartMate 3 (HM3) compared to the HeartMate (HMII). We sought to evaluate the individual and interactive effects of pre-specified patient subgroups (age, sex, race, therapeutic intent (BTT/BTC/DT) and severity of illness) on primary endpoint outcomes in MOMENTUM 3 patients implanted with HM3 and HMII.
Source: The Journal of Heart and Lung Transplantation - November 3, 2017 Category: Transplant Surgery Authors: Daniel J. Goldstein, Mandeep R. Mehra, Yoshifumi Naka, Christopher Salerno, Nir Uriel, David Dean, Akinobu Itoh, Francis D. Pagani, Eric R. Skipper, Geetha Bhat, Nirav Raval, Brian A. Bruckner, Jerry D. Estep, Rebecca Cogswell, Carmelo Milano, Lahn Fendel Source Type: research

Ischemic Stroke and Subsequent Thrombosis within a HeartMate 3 Left Ventricular Assist System: A Cautionary Tale
Introduction of the centrifugal continuous flow-pump, the Heartmate 3 Left Ventricular Assist System (LVAS) has been heralded with the unique observation that de-novo pump thrombosis has not been reported to occur with this device in the pivotal clinical trials.1,2 While engineering principles inherent in this LVAS obviate the initial development of thrombosis within the pump, they cannot protect against ingestion of thrombus or other circulating materials. Similarly, if such ingested material (or thrombus) remains trapped within the device and materially influences its function, it may set-up a nidus for propagation of th...
Source: The Journal of Heart and Lung Transplantation - November 6, 2017 Category: Transplant Surgery Authors: Ivan Netuka, Mandeep R. Mehra Source Type: research

Impact of age, sex, therapeutic intent, race and severity of advanced heart failure on short-term principal outcomes in the MOMENTUM 3 trial
In this study we sought to evaluate the individual and interactive effects of pre-specified patient subgroups (age, sex, race, therapeutic intent [bridge to transplant/bridge to candidacy/destination therapy] and severity of illness) on primary end-point outcomes in MOMENTUM 3 patients implanted with HM3 and HMII devices.
Source: The Journal of Heart and Lung Transplantation - November 3, 2017 Category: Transplant Surgery Authors: Daniel J. Goldstein, Mandeep R. Mehra, Yoshifumi Naka, Christopher Salerno, Nir Uriel, David Dean, Akinobu Itoh, Francis D. Pagani, Eric R. Skipper, Geetha Bhat, Nirav Raval, Brian A. Bruckner, Jerry D. Estep, Rebecca Cogswell, Carmelo Milano, Lahn Fendel Tags: Original Clinical Science Source Type: research

Intraoperative extracorporeal membrane oxygenation versus cardiopulmonary bypass for lung transplantation: A meta-analysis
Conclusion: ECMO support for LuTx showed better clinical outcomes compared to CPB.
Source: European Respiratory Journal - December 6, 2017 Category: Respiratory Medicine Authors: Magouliotis, D., Svokos, A., Svokos, K., Olland, A., Massard, G., Tasiopoulou, V., Zacharoulis, D. Tags: Transplantation Source Type: research

Comparison of a portable device versus a specific spirometer for cough flow testing
Conclusions: In this evaluation, including patients with heterogeneous disorders and normal controls, CPF readings were on average significantly higher when measured using the equipment with the CPF testing dedicated software; moreover this device allows for a better assessment of the cough maneuvers including visualization of the cough flow-volume loops.
Source: European Respiratory Journal - December 6, 2017 Category: Respiratory Medicine Authors: Maia Silva, A., Viamonte, S., Machado Vaz, I., Almeida, M., Gomes, A., Silva, F., Winck, J. C. Tags: Monitoring Airway Disease Source Type: research

Anticoagulation with VADs and ECMO: walking the tightrope.
Authors: Raffini L Abstract The evolution of devices for mechanical circulatory support (MCS), including ventricular assist devices (VADs) for patients with heart failure and extracorporeal membrane oxygenation (ECMO) for patients with acute cardiac or respiratory failure, has improved survival for subsets of critically ill children and adults. The devices are intricate and complex, allowing blood to bypass the heart or lungs (or both). As blood flows through these artificial devices, normal hemostasis is disrupted, coagulation is promoted, and in the absence of anticoagulation, a thrombus may form in the device, r...