HIV incidence among women using intramuscular depot medroxyprogesterone acetate, a copper intrauterine device, or a levonorgestrel implant for contraception: a randomised, multicentre, open-label trial

This study is registered with ClinicalTrials.gov, number NCT02550067.FindingsBetween Dec 14, 2015, and Sept 12, 2017, 7830 women were enrolled and 7829 were randomly assigned to the DMPA-IM group (n=2609), the copper IUD group (n=2607), or the LNG implant group (n=2613). 7715 (99%) participants were included in the modified intention-to-treat population (2556 in the DMPA-IM group, 2571 in the copper IUD group, and 2588 in the LNG implant group), and women used their assigned method for 9567 (92%) of 10 409 woman-years of follow-up time. 397 HIV infections occurred (incidence 3·81 per 100 woman-years [95% CI 3·45–4·21]): 143 (36%; 4·19 per 100 woman-years [3·54–4·94]) in the DMPA-IM group, 138 (35%: 3·94 per 100 woman-years [3·31–4·66]) in the copper IUD group, and 116 (29%; 3·31 per 100 woman-years [2·74–3·98]) in the LNG implant group. In the modified intention-to-treat analysis, the hazard ratios for HIV acquisition were 1·04 (96% CI 0·82–1·33, p=0·72) for DMPA-IM compared with copper IUD, 1·23 (0·95–1·59, p=0·097) for DMPA-IM compared with LNG implant, and 1·18 (0·91–1·53, p=0·19) for copper IUD compared with LNG implant. 12 women died during the study: six in the DMPA-IM group, five in the copper IUD group, and one in the LNG implant group. Serious adverse events occurred in 49 (2%) of 2609 participants in the DMPA-IM group, 92 (4%) of 2607 participants in the copper IUD group, and 78 (3%) of 2613 participants in the LNG implant gro...
Source: The Lancet - Category: General Medicine Source Type: research