Estimating metabolic rate from International Organization for Standardization heart rate method and two walking equations

Ind Health. 2024 Apr 3. doi: 10.2486/indhealth.2024-0015. Online ahead of print.ABSTRACTAssigning a value for metabolic rate is central to heat stress assessment. ISO 8996 describes a predictive method for walking based on the American College of Sports Medicine (ACSM) method and another generalized method based on average heart rate. In addition, the US Army uses the load carriage decision aid (LCDA) predictive equation to estimate metabolic rate. The purpose of this study was to assess the accuracy/bias and precision of the ISO heart rate method and the ACSM and LCDA equations. The laboratory database included metabolic rate, heart rate, treadmill speed, and grade during a progressive heat stress protocol. Treadmill speed and grade were set to represent one of three metabolic rates. Accuracy and precision were assessed with Bland-Altman plots. All three methods had good accuracy (low bias). For precision, the ISO heart rate method had a root mean square error (RMSE) of 34 W and 11% when adjusted for repeated measures. The RMSE for two equations was 20 W and 7%. Although the heart method had less accuracy, its application is more generalizable. The heart rate method should be used below the occupational exposure limit to avoid a bias toward higher predicted values due to heat strain.PMID:38569893 | DOI:10.2486/indhealth.2024-0015
Source: Industrial Health - Category: Occupational Health Authors: Source Type: research