Exploring complications following cranioplasty after decompressive hemicraniectomy: A retrospective bicenter assessment of autologous, PMMA and CAD implants

AbstractCranioplasty (CP) after decompressive hemicraniectomy (DHC) is a common neurosurgical procedure with a high complication rate. The best material for the repair of large cranial defects is unclear. The aim of this study was to evaluate different implant materials regarding surgery related complications after CP. Type of materials include the autologous bone flap (ABF), polymethylmethacrylate (PMMA), calcium phosphate reinforced with titanium mesh (CaP-Ti), polyetheretherketone (PEEK) and hydroxyapatite (HA). A retrospective, descriptive, observational bicenter study was performed, medical data of all patients who underwent CP after DHC between January 1st, 2016 and December 31st, 2022 were analyzed. Follow-up was until December 31st, 2023. 139 consecutive patients with a median age of 54  years who received either PMMA (56/139; 40.3%), PEEK (35/139; 25.2%), CaP-Ti (21/139; 15.1%), ABF (25/139; 18.0%) or HA (2/139; 1.4%) cranial implant after DHC were included in the study. Median time from DHC to CP was 117 days and median follow-up period was 43 months. Surgical site infection w as the most frequent surgery-related complication (13.7%; 19/139). PEEK implants were mostly affected (28.6%; 10/35), followed by ABF (20%; 5/25), CaP-Ti implants (9.5%; 2/21) and PMMA implants (1.7%, 1/56). Explantation was necessary for 9 PEEK implants (25.7%; 9/35), 6 ABFs (24.0%; 6/25), 3 CaP-Ti implants (14.3%; 3/21) and 4 PMMA implants (7.1%; 4/56). Besides infection, a postoperative ...