Filtered By:
Specialty: Cardiology
Condition: Bleeding
Procedure: Transplants

This page shows you your search results in order of date.

Order by Relevance | Date

Total 51 results found since Jan 2013.

MAGT1 Deficiency Dysregulates Platelet Cation Homeostasis and Accelerates Arterial Thrombosis and Ischemic Stroke in Mice
CONCLUSIONS: These results suggest that MAGT1 and TRPC6 are functionally linked. Therefore, deficiency or impaired functionality of MAGT1 could be a potential risk factor for arterial thrombosis and stroke.PMID:37381987 | DOI:10.1161/ATVBAHA.122.318115
Source: Arteriosclerosis, Thrombosis and Vascular Biology - June 29, 2023 Category: Cardiology Authors: Sanjeev Kiran Gotru Elmina Mammadova-Bach Georgios Sogkas Michael K Schuhmann Karen Schmitt Peter Kraft Sabine Herterich Medina Mamtimin Akif Pinarci Sarah Beck Simon Stritt Han Chao Pengxuan Ren Jean-No ël Freund Christian Klemann Felix C Ringshausen Jo Source Type: research

Identifying patients at risk: multi ‐centre comparison of HeartMate 3 and HeartWare left ventricular assist devices
ConclusionsHM3 patients have a significantly better survival and a lower incidence of ischaemic strokes and pump thrombosis than HVAD patients. This survival difference persisted after 2  years of implantation. Additional research using post-operative variables is warranted to identify which HVAD patients need an upgrade to HM3 or expedited transplantation.
Source: ESC Heart Failure - February 17, 2023 Category: Cardiology Authors: Lieke Numan, Daniel Zimpfer, Osnat Itzhaki Ben Zadok, Emmeke Aarts, Michiel Morshuis, Sabina P.W. Guenther, Julia Riebandt, Dominik Wiedemann, Faiz Z. Ramjankhan, Anne ‐Marie Oppelaar, Tuvia Ben‐Gal, Binyamin Ben‐Avraham, Folkert W. Asse Tags: Original Article Source Type: research

Clinical outcomes of grafted vs. percutaneous axillary intra-aortic balloon pump support as a bridge to transplantation: a propensity score-matched analysis
ConclusionIn the propensity score matching analysis, there were not any significant differences between the two groups in IABP-related complications, in-hospital mortality, and late survival. The percutaneous technique provided a shorter operation time and less requirement of transfusion and re-exploration for bleeding compared to the grafted technique. The percutaneous technique might be favorable when feasible.
Source: Heart and Vessels - November 1, 2022 Category: Cardiology Source Type: research

Contemporary Mechanical Circulatory Support With Continuous-Flow Biventricular Assist Devices: A Systematic Review
As the incidence of heart failure increases, so too has that of biventricular failure. While transplantation remains the gold standard therapy for end-stage heart failure, the limited organ supply has increased the need for durable mechanical circulatory support. We therefore sought to conduct a systematic review of continuous-flow ventricular assist devices in a biventricular configuration (CF-BiVAD). An electronic search of PubMed and Cumulative Index to Nursing and Allied Health Literature (CINAHL) databases was performed using the keyword “BIVAD.” Studies were reviewed to identify discrete variables, including impl...
Source: Cardiology in Review - June 10, 2022 Category: Cardiology Tags: Review Articles Source Type: research

Comparing short ‐term/long‐term outcomes of heart transplants that occur inside and outside of normal working hours
ConclusionThere was no significant difference in clinical outcomes between heart transplants taking place inside or outside of working hours. A high quality of care can be provided for heart transplant patients even during after hours.
Source: ESC Heart Failure - April 23, 2022 Category: Cardiology Authors: Hidefumi Nishida, Christopher Salerno, David Onsager, Tae Song, Ann Nguyen, Jonathan Grinstein, Bow Chung, Bryan Smith, Sara Kalantari, Nitasha Sarswat, Gene Kim, Sean Pinney, Valluvan Jeevanandam, Takeyoshi Ota Tags: Original Article Source Type: research

Troubleshooting Left Ventricular Assist Devices: Modern Technology and Its Limitations
AbstractPurpose of reviewAs the incidence of heart failure continues to rise, modern generation left ventricular assist devices (LVADs) have become the primary therapeutic modality used as both bridge to transplant (BTT) and destination therapy (DT) in patients with acute and chronic heart failure. This review aims to highlight the progression of LVAD technology, outline LVAD complications and manifestations, and provide evidence-based therapeutic methods to troubleshoot such adverse events.Recent findingsDespite modern innovation, LVAD adverse events continue to hinder the progress of HF paradigms and are associated with ...
Source: Current Treatment Options in Cardiovascular Medicine - August 2, 2021 Category: Cardiology Source Type: research

Left Ventricular Assist Device
Left ventricular assist devices (LVADs) are indicated in inotrope-dependent heart failure (HF) patients with pure or predominant LV dysfunction. Survival benefit is less clear in ambulatory, advanced HF. Timing is crucial: early, unnecessary exposure to the risks of surgery, and device-related complications (infections, stroke, and bleeding) should be weighed against the probability of dying or developing irreversible right ventricular and/or end-organ dysfunction while deferring implant. The interplay between LVAD and heart transplantation depends largely on donor availability and allocation rules. Postoperatively, qualit...
Source: Heart Failure Clinics - July 21, 2021 Category: Cardiology Authors: Maria Frigerio Source Type: research

Complications of left ventricular assist devices causing high urgency status on waiting list: impact on outcome after heart transplantation
ConclusionsLeft ventricular assist device therapy can impair the outcome after HTx. However, the occurrence of LVAD complications may not impact on outcome after HTx. Thus, we cannot support the prioritization or discrimination of HTx candidates according to distinct mechanical circulatory support ‐associated complications. Future allocation strategies have to respect that device‐related complications may define urgency but do not impact on the outcome after HTx.
Source: ESC Heart Failure - March 29, 2021 Category: Cardiology Authors: Moritz Benjamin Immohr, Udo Boeken, Franziska Mueller, Emir Prashovikj, Michiel Morshuis, Charlotte B öttger, Hug Aubin, Jan Gummert, Payam Akhyari, Artur Lichtenberg, René Schramm Tags: Original Research Article Source Type: research