Modified ablation index: a novel determinant of a successful first-pass left atrial posterior wall isolation

This study aimed to evaluate the performance of a modified ablation index (AI) (AI/bipolar voltage along the ablation line) for predicting a durable LAPWI. The study included 55 consecutive patients, aged 65  ± 11 years, who underwent an electroanatomic mapping-guided LAPWI of AF. The association between the gaps (first-pass LAPWI failure and/or acute LAPW reconnections), voltage amplitude along the roof and floor lines, and thickness of the LAPW was investigated. Gaps occurred in 22 patients (40% ) and in 26 (8%) of the 330 line segments. Gaps were associated with a relatively high bipolar voltage (3.38 ± 1.83 vs. 1.70 ± 1.12 mV,P <  0.0001) and thick LA wall (2.52 ± 1.15 vs. 1.42 ± 0.44 mm,P <  0.0001). A modified AI ≤ 199 AU/mV, bipolar voltage ≥ 2.64 mV, wall thickness ≥ 2.04 mm, and roof ablation line ≥ 43.4 mm well predicted gaps (AUCs: 0.783, 0.787, 0.858, and 0.752, respectively). A high-voltage zone, thick LAPW, and long roof ablation line appeared to b e determinants of gaps, and a modified AI ≥ 199 AU/mV along the ablation lines appeared to predict an acute durable LAPWI.
Source: Heart and Vessels - Category: Cardiology Source Type: research