Detecting Progression in Patients With Different Clinical Presentations of Primary Open-angle Glaucoma

Conclusions: While both RNFLT and VF parameters showed comparable abilities to identify progression across the different classifications, RNFLT assessment may be better suited to monitor progression, particularly among patients with elevated intraocular pressure and those who present with only GVF defect at baseline.
Source: Journal of Glaucoma - Category: Opthalmology Tags: Glaucoma Care: Original Studies Source Type: research