Continuous Body Temperature Monitoring to Improve the Diagnosis of Female Infertility.

Conclusions Continuous body temperature monitoring with a vaginal biosensor can improve the standard diagnostic procedures used to determine ovulatory dysfunction, especially if dysfunction is due to luteal phase deficiency and polycystic ovary syndrome. Analysis of the lowest daily body temperature combined with the basal body temperature measurements used in fertility awareness methods may be equieffective to continuous body temperature measurements with OvulaRing. The results of this study show that a revised diagnostic approach using fewer hormonal assessments combined with continuous body temperature monitoring can reduce the number of appointments in an infertility clinic as well as the costs. PMID: 32675832 [PubMed]
Source: Geburtshilfe und Frauenheilkunde - Category: OBGYN Tags: Geburtshilfe Frauenheilkd Source Type: research