Case report: electrical automated massage chair use can induce osteoporotic vertebral compression fracture

We present a case of an elderly woman diagnosed with acute OVCF of the thoracic spine after using an EAMC. The patient had no risk factor for fragility fracture and experienced an abrupt onset of severe upper back pain while using EAMC. Imaging studies revealed an isolated acute compression fracture at T8 vertebra (AO classification type A1) while dual-energy X-Ray absorptiometry scan confirmed osteoporosis. The patient was treated with a plastic orthosis and oral medications for osteoporosis. After 6-months follow-up, the patient showed union of the fractured T8 vertebra and no remaining symptoms. This case highlights that OVCF can be induced by EAMC. Therefore, patients with or at risk for osteoporosis should be cautious while opting for deep tissue massage using EAMC.
Source: Osteoporosis International - Category: Orthopaedics Source Type: research