Allogeneic Blood Product Usage in Coronary Artery Bypass Grafting (CABG) with minimalized Extracorporeal Circulation System (MECC) Versus Standard On-Pump Coronary Artery Bypass Grafting.

CONCLUSION: Application of MECC as on-pump coronary artery bypass graft (CABG) results in significantly lower ABPT as well as shorter ICU and in-hospital stay. In order to achieve these benefits of MECC autologous retrograde priming, Bispectral index (BIS) monitoring, intraoperative cell salvage, meticulous hemostasis and strict peri- and postoperative volume management are crucial. PMID: 27499818 [PubMed]
Source: Open Cardiovascular Medicine Journal - Category: Cardiology Tags: Open Cardiovasc Med J Source Type: research