Risk of infections related to endovascular catheters and cardiac implantable devices in hemodialysis patients

J Vasc Access. 2024 Mar 20:11297298241240502. doi: 10.1177/11297298241240502. Online ahead of print.ABSTRACTPatients requiring dialysis are extremely vulnerable to infectious diseases. The high burden of comorbidities and weakened immune system due to uremia and previous immunosuppressive therapy expose the patient on dialysis to more infectious events than the general population. The infectious risk is further increased by the presence of endovascular catheters and implantable cardiologic devices. The former is generally placed as urgent vascular access for dialysis and in subjects requiring hemodialysis treatments without autogenous arteriovenous fistula. The high frequency of cardiovascular events also increases the likelihood of implanting indwelling implantable cardiac devices (CIED) such as pacemakers (PMs) and defibrillators (ICDs). The simultaneous presence of CVC and CIED yields an increased risk of developing severe prosthetic device-associated bloodstream infections often progressing to septicemia. Although, antibiotic therapy is the mainstay of prosthetic device-related infections, antibiotic resistance of biofilm-residing bacteria reduces the choice of infection eradication. In these cases, the resolution of the infection process relies on the removal of the prosthetic device. Compared to CVC removal, the extraction of leads is a more complex procedure and poses an increased risk of vessel tearing. As a result, the prevention of prosthetic device-related infectio...
Source: The Journal of Vascular Access - Category: Surgery Authors: Source Type: research