Analysis of Efficacy and Safety of Small-Volume-Plasma Artificial Liver Model in the Treatment of Acute-On-Chronic Liver Failure

Physiol Res. 2023 Dec 31;72(6):767-782. doi: 10.33549/physiolres.935158.ABSTRACTTo explore the efficacy and safety of a small-volume-plasma artificial liver support system (ALSS) in the treatment of acute-on-chronic liver failure (ACLF). A retrospective analysis was performed. All ACLF patients received ALSS of plasma exchange & double plasma molecular absorb system (PE+DPMAS) treatment, and successfully completed this treatment. Patients were divided into small-volume and half-volume plasma groups. We compared the changes of the indicators on liver function, kidney function, blood coagulation function, and blood ammonia level before and after PE+DPMAS treatment; we compared the short-term and long-term curative effects between small-volume and half-volume plasma groups; and the factors influencing Week 4 and Week 12 mortality of ACLF patients were analyzed. The Week 4 improvement rates were 63.96 % and 66.86 % in the small-volume and half-volume plasma groups, respectively. The Week 12 survival rates in the small-volume-plasma and half-volume plasma groups were 66.72 % and 64.61 %, respectively. We found several risk factors affecting Week 4 and Week 12 mortality. Kaplan-Meier survival curves suggested no significant difference in Week 4 and Week 12 survival rates between the small-volume and half-volume plasma groups (P=0.34). The small-volume-plasma PE+DPMAS treatment could effectively reduce bilirubin and bile acids, and this was an approach with high safety and few c...
Source: Physiological Research - Category: Physiology Authors: Source Type: research