High ‐power short‐duration versus low‐power long‐duration ablation for pulmonary vein isolation: A substudy of the AWARE randomized controlled trial

ConclusionsAn HPSD strategy was associated with significantly shorter procedural times with similar efficacy in terms of clinical arrhythmia recurrence. Importantly, there was no signal for increased harm with a HPSD strategy.
Source: Journal of Cardiovascular Electrophysiology - Category: Cardiology Authors: Tags: ORIGINAL ARTICLE Source Type: research