Novel ruthenium-doped vanadium carbide/polymeric nanohybrid sensor for acetaminophen drug detection in human blood

Int J Biol Macromol. 2023 Jun 10:125329. doi: 10.1016/j.ijbiomac.2023.125329. Online ahead of print.ABSTRACTThe use of advanced electroactive catalysts enhances the performance of electrochemical biosensors in real-time biomonitoring and has received much attention owing to its excellent physicochemical and electrochemical possessions. In this work, a novel biosensor was developed based on the electrocatalytic activity of functionalized vanadium carbide (VC) material, including VC@ruthenium (Ru), VC@Ru-polyaniline nanoparticles (VC@Ru-PANI-NPs) as non-enzymatic nanocarriers for the fabrication of modified screen-printed electrode (SPE) to detect acetaminophen in human blood. As-prepared materials were characterized using SEM, TEM, XRD, and XPS techniques. Biosensing was carried out using cyclic voltammetry and differential pulse voltammetry techniques and has revealed imperative electrocatalytic activity. A quasi-reversible redox method of the over-potential of acetaminophen increased considerably compared with that at the modified electrode and the bare SPE. The excellent electrocatalytic behaviour of VC@Ru-PANI-NPs/SPE is attributed to its distinctive chemical and physical properties, including rapid electron transfer, striking ᴫ-ᴫ interface, and strong adsorptive capability. This electrochemical biosensor exhibits a detection limit of 0.024 μM, in a linear range of 0.1-382.72 μM with a reproducibility of 2.45 % relative standard deviation, and a good recovery from 96...
Source: International Journal of Biological Macromolecules - Category: Biochemistry Authors: Source Type: research