Predictors of Serious Adverse Events and High-Level Cardiorespiratory Support in Patients Undergoing Transcatheter Pulmonary Vein Interventions

AbstractPatients with pulmonary vein stenosis (PVS) often require frequent transcatheter pulmonary vein (PV) interventions for management of restenosis. Predictors of serious adverse events (AEs) and need for high-level cardiorespiratory support (mechanical ventilation, vasoactive support, and/or extracorporeal membrane oxygenation) 48  h after transcatheter PV interventions have not been reported. This is a single-center retrospective cohort analysis of patients with PVS who underwent transcatheter PV interventions from 3/1/2014 to 12/31/2021. Univariate and multivariable analyses were performed using generalized estimating equa tions to account for within-patient correlation. 240 patients underwent 841 catheterizations involving PV interventions (median 2 catheterizations per patient [1,3]). At least one serious AE was reported in 100 (12%) cases, the most common of which were pulmonary hemorrhage (n = 20) and arrhythmia (n = 17). There were 14 severe/catastrophic AEs (1.7% of cases) including three strokes and one patient death. On multivariable analysis, age less than 6 months, low systemic arterial saturation (<  95% in patients with biventricular [BiV] physiology, <  78% in single ventricle [SV] physiology), and severely elevated mean PA pressure (≥ 45 mmHg in BiV, ≥ 17 mmHg in SV) were associated with SAEs. Age less than 1 year, hospitalization prior to catheterization, and moderate–severe RV dysfunction were associated with high-le...
Source: Mammalian Genome - Category: Genetics & Stem Cells Source Type: research