Hemodynamic Effects of Left Atrial or Left Ventricular Cannulation for Acute Circulatory Support in a Bovine Model of Left Heart Injury
Our objective was to examine the hemodynamic effects of a trans-aortic axial flow catheter (Impella CP) in the left ventricle (LV) versus left atrial (LA) to femoral artery bypass using a centrifugal pump (TandemHeart: TH) in a bovine model of acute LV injury. In three male calves, we performed sequential activation of a CP then TH device in each animal. After 60 minutes of left anterior descending artery ligation, a CP was activated at maximal power. The CP was then removed and the TH activated at 5,500 then a maximum of 7,500 rotations per minute (RPM). The CP generated a maximum 3.1 ± 0.2 L/minute (LPM) of flow, wherea...
Source: ASAIO Journal - May 1, 2015 Category: Medical Equipment Tags: Adult Circulatory Support Source Type: research

Spectroscopic and Morphological Characterization of Inflow Cannulas of Left Ventricular Assist Devices
In this study, we carried out an in-depth physicochemical characterization of two commercially available LVADs by means of field emission gun scanning electron microscopy, energy dispersive X-ray, and X-ray photoelectron spectra. Our results show that, despite both pumps share the same physicochemical concepts, major differences can be identified in the surface nature, morphology, and chemical composition of their inflow cannulas
Source: ASAIO Journal - March 1, 2015 Category: Medical Equipment Tags: Adult Circulatory Support Source Type: research

Cavopulmonary Support with a Microaxial Pump for the Failing Fontan Physiology
The number of patients with the failing Fontan physiology is increasing. We tested a novel in situ microaxial pump (Impella) to support the failing atrio-pulmonary Fontan circulation in an acute pig model. A Fontan model was established in eight juvenile pigs by connecting the right atrium to the main pulmonary artery after tricuspid valve destruction. The Impella pump was inserted retrograde from the distal main pulmonary artery into the right atrium. Hemodynamics, blood gas, and echocardiographic data were compared among baseline, pure Fontan physiology (10 minutes), and mechanically assisted Fontan physiology (up to 12 ...
Source: ASAIO Journal - December 31, 2014 Category: Medical Equipment Tags: Pediatric Circulatory Support Source Type: research

Platelet-Derived Microparticles Generated by Neonatal Extracorporeal Membrane Oxygenation Systems
The objective of this study was to compare PMP generation in five different neonatal ECMO systems, using a simulated circuit with swine blood at 300 ml/min for 4 hours. Systems were composed of both newer components (centrifugal pump and hollow-fiber oxygenator) and traditional components (roller-head pump and silicone membrane oxygenator). Free plasma hemoglobin levels were measured as an indicator of hemolysis and flow cytometry-measured PMP. Hemolysis generated in all ECMO systems was similar to that observed in noncirculated static blood (p = 0.48). There was no difference in net PMP levels between different oxygenator...
Source: ASAIO Journal - December 31, 2014 Category: Medical Equipment Tags: Pediatric Circulatory Support Source Type: research

Cardiac Function After Acute Support With Direct Mechanical Ventricular Actuation in Chronic Heart Failure
This study evaluated hemodynamics and load-independent systolic/diastolic cardiac function before/after acute support (2 hours) using DMVA in small hearts with induced chronic failure. Chronic heart failure was created in seven small dogs (15 ± 2 kg) via either serial coronary microembolizations or right-ventricular overdrive pacing. Dogs were instrumented to measure cardiac output, hemodynamic pressures, left ventricular volumes for pressure–volume analysis via preload reduction. Temporary cardiac support using a DMVA device was instituted for 2 hours. Hemodynamic and mechanical assessments, including dobutamine doseâ€...
Source: ASAIO Journal - November 1, 2014 Category: Medical Equipment Tags: Pediatric Circulatory Support Source Type: research