Filtered By:
Source: ASAIO Journal

This page shows you your search results in order of relevance.

Order by Relevance | Date

Total 95 results found since Jan 2013.

Increased Stroke Risk in Children and Young Adults on Extracorporeal Life Support with Carotid Cannulation
Patients on extracorporeal life support (ECLS) are at risk for central nervous system (CNS) injury. One potentially modifiable risk factor is site of arterial cannulation in venoarterial (VA) ECLS, as in most cases one can choose the femoral or carotid artery. There is acute alteration in cerebral blood flow with carotid cannulation, potentially increasing the risk of stroke. Children may have lower risk of stroke with carotid cannulation compared with adults because of impaired cerebral circulation with aging. Our objective was to evaluate risk of stroke with carotid versus femoral cannulation and determine whether this d...
Source: ASAIO Journal - September 1, 2019 Category: Medical Devices Tags: Pediatric Circulatory Support Source Type: research

Smoking and the Risk of Stroke in Patients with a Left Ventricular Assist device
There are limited data on the association of smoking with the risk of stroke following left ventricular assist device (LVAD) implantation. We designed this study to analyze the impact of smoking status at the time of LVAD implantation on stroke. We hypothesized that current smokers are at increased risk of stroke when compared with patients who were former or never smokers. The study population comprised of 369 patients in the University of Rochester Medical Center LVAD database, implanted with an LVAD between 2008 and 2018. Patients were stratified as current smoker (smoking within 30 days before LVAD implantation), forme...
Source: ASAIO Journal - November 1, 2021 Category: Medical Devices Tags: Adult Circulatory Support Source Type: research

What Causes LVAD-Associated Ischemic Stroke? Surgery, Pump Thrombosis, Antithrombotics, and Infection
Acute ischemic stroke (AIS) is a major complication in left ventricular assist device (LVAD) population. A better understanding of clinical risk factors associated with AIS may help mitigate risk of stroke. We reviewed prospectively collected data of 477 LVAD patients from a tertiary center from October 1, 2004 to December 31, 2016. Supplemental data abstraction was performed on patients with AIS. Fifty-seven (12%) developed 61 AIS. Of 61, 17 (28%) AIS occurred perioperatively. The median time from implant to perioperative AIS was 5 days (interquartile range: 3–9). Pump thrombosis accounted for 19 (31%) of 61 AIS, and 7 ...
Source: ASAIO Journal - November 1, 2019 Category: Medical Devices Tags: Adult Circulatory Support Source Type: research

Fibrinogen Albumin Ratio and Ischemic Stroke During Venoarterial Extracorporeal Membrane Oxygenation
Fibrinogen is a clotting factor and a major determinant of platelet aggregation. Albumin, on the other hand, inhibits platelet function and thrombus formation. Taken together, an elevated fibrinogen albumin ratio (FAR) has been described as a marker of disease severity during prothrombotic conditions. We evaluated the association of FAR and ischemic stroke during venoarterial extracorporeal membrane oxygenation (VA ECMO) support. A single center, retrospective study was performed including all adult patients placed on VA ECMO. FAR was calculated from fibrinogen and albumin measurements in the first 24 hours of VA-ECMO init...
Source: ASAIO Journal - February 28, 2020 Category: Medical Devices Tags: Adult Circulatory Support Source Type: research

Ischemic Stroke and Intracranial Hemorrhages During Impella Cardiac Support
Impella is a percutaneously placed, ventricular assist device for short-term cardiac support. We aimed to study acute neurologic complications during short-term cardiac support with Impella. We reviewed prospectively collected data of 79 consecutive persons implanted with Impella at a single tertiary center. Acute neurologic events (ANE) were defined as ischemic strokes or intracranial hemorrhages. Among those with ANE, specific causes of ischemic and hemorrhagic events were collected and discussed. Of 79 persons with Impella with median 8 days of support (range 1–33 days), six (7.5%) developed ANE at a median of 5 days ...
Source: ASAIO Journal - July 30, 2020 Category: Medical Devices Tags: Case Report Source Type: research

Comparison of Neurologic Event Rates Among HeartMate II, HeartMate 3, and HVAD
Strokes remain a leading cause of morbidity and mortality in patients with ventricular assist devices (VADs). Varying study populations, event definitions, and reporting methods make direct comparison of neurologic event risk across clinical trials and registries challenging. We aim to highlight important differences among major VAD studies and standardize rates of neurologic events to facilitate a comprehensive and objective comparison. We systematically identified and analyzed key clinical trials and registries evaluating the HeartMate II (HMII), HeartMate 3 (HM3), and HVAD devices. Reported neurologic events were nonexc...
Source: ASAIO Journal - May 30, 2020 Category: Medical Devices Tags: Adult Circulatory Support Source Type: research

Hydrodynamic and Geometric Behavior of Two Pericardial Prostheses Implanted in Small Aortic Roots
Hydrodynamic performance of stented bioprostheses is far below that of the native valve. One of the reasons is that the internal diameter of the prosthesis is usually smaller than that of the native valve. However, other valve characteristics are also important in generating the pressure drop. We aimed to assess, in an ex vivo pulsatile mock loop, the hydrodynamic behavior of two bioprostheses, Trifecta and Mitroflow, to ascertain which geometric terms are limiting factors in hydrodynamic performance. At stroke volumes between 30 and 60 ml, Trifecta showed lower pressure drop, energy dissipation and valve resistance, and...
Source: ASAIO Journal - December 22, 2017 Category: Medical Devices Tags: Clinical Cardiovascular Source Type: research

Individualized Antithrombotic Therapy in Heartware HVAD Recipients
There are no evidence-based guidelines for antithrombotic therapy in left ventricular assist device patients. We evaluated the efficacy of a multi-agent, test-guided protocol, which remained consistent throughout our use of the Heartware HVAD. Thrombelastography and platelet function analyzer (PFA)-100 guide antiplatelet titration. Goals are normal kaolin thrombelastography maximum amplitude and prolonged PFA-100. We analyzed incidence and rates of nonprocedural bleeding, stroke, and pump thrombosis for all 81 primary Heartware left ventricular assist devices implanted since 2011. For each event, we examined whether each t...
Source: ASAIO Journal - December 28, 2018 Category: Medical Devices Tags: Adult Circulatory Support Source Type: research

Atrial Fibrillation Is Not Associated With Thromboembolism in Left Ventricular Assist Device Patients: A Systematic Review and Meta-Analysis
Atrial fibrillation (AF) is a well-established risk factor of thromboembolism (TE). Thromboembolism is one of the most common complications in patients supported by continuous-flow left ventricular assisted devices (CF-LVADs). However, the association between AF and TE complications in this population is controversial. We conducted a systematic review and meta-analysis to assess the association between AF and overall TE, stroke, and device thrombosis events in CF-LVAD patients. We performed a comprehensive literature search through September 2017 in the databases of MEDLINE and EMBASE. Included studies were prospective or ...
Source: ASAIO Journal - July 1, 2019 Category: Medical Devices Tags: Adult Circulatory Support Source Type: research

Effect of Preoperative Atrial Fibrillation on Patients with Chronic Heart Failure Who Undergo Long-Term Continuous-Flow LVAD Implantation
Although preoperative atrial fibrillation (AF) is common in patients undergoing continuous-flow left ventricular assist device (CF-LVAD) implantation, how AF affects outcomes remains unclear. We analyzed our single-center experience with CF-LVAD implantation to determine whether preoperative AF was associated with inferior outcomes. From November 2003 through March 2016, 526 patients with chronic heart failure underwent implantation with the HeartMate II (HMII; n = 403) or HeartWare VAD (HVAD; n = 123). We identified 229 patients (165 HMII, 65 HVAD) who had preoperative AF and compared them with non–preoperative AF patie...
Source: ASAIO Journal - August 28, 2018 Category: Medical Devices Tags: Adult Circulatory Support Source Type: research

Effect of Outflow Graft Size on Flow in the Aortic Arch and Cerebral Blood Flow in Continuous Flow Pumps: Possible Relevance to Strokes
One of the most devastating complications of continuous flow left ventricular devices (CFLVADS) is stroke, with a higher incidence in HeartWare Ventricular Assist Device (HVAD) as compared with HEARTMATE II. The reason for the observed difference in stroke rates is unclear. Because outflow graft diameters are different, we hypothesized that this could contribute to the difference in stroke rates. A computational fluid–structure interaction model was created from the computed tomography (CT) scan of a patient. Pressures were used as the boundary condition and the flow through the cerebral vessels was derived as outputs. F...
Source: ASAIO Journal - February 25, 2017 Category: Medical Equipment Tags: Adult Circulatory Support Source Type: research

Permanent Atrial Fibrillation and 2 Year Clinical Outcomes in Patients with a Left Ventricular Assist Device Implant
Atrial fibrillation (AF) may increase the risk of thromboembolic (TE) complications in patients with left ventricular assist devices (LVADs). In a single-center study, we investigated 205 patients with sinus rhythm (SR group) and 117 patients with AF (AF group). Our main read outs were 2 year overall survival (primary end point), perioperative right heart failure (RHF), and 2 year freedom from stroke, pump thrombosis, and gastrointestinal bleeding (secondary end points). Oral anticoagulation was performed with phenprocoumon (international normalized ratio target range: 2.3–2.8) and aspirin (100 mg/day). Propensity scor...
Source: ASAIO Journal - June 29, 2017 Category: Medical Devices Tags: Adult Circulatory Support Source Type: research

Salutary Effects of the PULVAD, a Novel Implantable Counterpulsation Assist Device, on Cardiac Mechanoenergetics
In conclusion, the PULVAD unloads the failing LV, optimizes LV mechanoenergetics, and augments coronary blood flow. These salutary effects of short-term PULVAD support provide the foundation for long-term testing.
Source: ASAIO Journal - July 1, 2019 Category: Medical Devices Tags: Adult Circulatory Support Source Type: research

Adverse Event Profile Associated with Prolonged Use of CentriMag Ventricular Assist Device for Refractory Cardiogenic Shock
In conclusion, temporary VAD with CentriMag support is an effective treatment for patients in refractory cardiogenic shock. Despite its side effect, profile including a high rate of blood transfusion early in the immediate postoperative period of CentriMag support, aggressive use of the CentriMag support device has acceptable survival to discharge and 1 year survival.
Source: ASAIO Journal - November 1, 2019 Category: Medical Devices Tags: Adult Circulatory Support Source Type: research