Statin Therapy in HIGH-Risk Individuals with NORMal Coronary Arteries: The HIGH-NORM Study
CONCLUSIONS: Statin use was not associated with cardiovascular risk reduction in high-risk persons with normal or near normal coronary arteries. More individualised lipid-lowering therapy may benefit this population.PMID:34334544 | DOI:10.5551/jat.63004
Source: Journal of Atherosclerosis and Thrombosis - August 2, 2021 Category: Cardiology Authors: Kyeong-Hyeon Chun Jung Mi Park Chan Joo Lee Jaewon Oh Sungha Park Seok-Min Kang Sang-Hak Lee Source Type: research

E-127 Combined MIVI-Q™ aspiration catheter-Stent retriever approach to stroke thrombectomy: Preliminary clinical experience
ConclusionsThis preliminary study found good efficacy and safety for MIVI Q™ aspiration catheters used in combination with stent-retriever devices.TableShows main Angiographic, Clinical efficacy and safety outcomes.Abstract E-127 Table 1Angiographic outcomes and clinical efficacyGroin-puncture-to-revascularization [min], median (IQR) 42 (22-66) QTM tFPE, n (%) 22 (42.3) QTM FPE, n (%) 25 (48) mTICI 3, n (%) 28 (53.8) mTICI 2c-3, n (%) 35 (67.3) mTICI ≥ 2b, n (%) 47 (90.4) mRS 0-2 at 90 days, n (%) 24 (46.2) sICH, n (%) 1 (1.9) Serious device-related adverse events, n (%) 0 (0) Serious procedure related adverse ev...
Source: Journal of NeuroInterventional Surgery - July 26, 2021 Category: Neurosurgery Authors: Remollo, S. Tags: Electronic poster abstracts Source Type: research

O-005 Comparison of on-label versus off-label treatment of intracranial aneurysms with the pipeline embolization devices
ConclusionIn real-world practice, off-label uses of PED can achieve similar safety and efficacy to on-label uses, though there may be a slightly higher rate of ischemic complications in off-label uses. Expert judgment is a useful supplement to official guidelines when assessing reasonable PED use beyond its approved indications.Disclosures S. Cler: None. D. Lauzier: None. A. Kansagra: 2; C; Penumbra, Microvention, iSchemaView.
Source: Journal of NeuroInterventional Surgery - July 26, 2021 Category: Neurosurgery Authors: Cler, S., Lauzier, D., Kansagra, A. Tags: Oral abstracts Source Type: research

P-042 Initial experience with tenecteplase as the intravenous thrombolytic of choice before mechanical thrombectomy for large vessel occlusion acute ischemic stroke
ConclusionIntravenous TNK in patients with LVOAIS is feasible, safe and effective. In our cohort from ‘real world’ patients, TNK was associated with lower need for MT, high recanalization rates and shorter hospitalization.Disclosures U. Ugur: None. S. Platko: None. D. Peters: None. F. Bensabeur: None. J. Terry: None. B. Ludwig: None. E. Cheng-Ching: None.
Source: Journal of NeuroInterventional Surgery - July 26, 2021 Category: Neurosurgery Authors: Ugur, U., Platko, S., Peters, D., Bensabeur, F., Terry, J., Ludwig, B., Cheng-Ching, E. Tags: Oral poster abstracts Source Type: research

E-004 Focal intracranial vasculopathy as a manifestation of COVID-19-associated acute ischemic stroke
ConclusionTo our knowledge, our case is the first to illustrate the potential for COVID-19 infection to present as a focal intracranial vasculopathy in an otherwise healthy young-patient, resulting in acute ischemic stroke without an underlying hypercoagulable state. Rescue intracranial stenting was necessary to maintain vessel patency and restore intracranial flow.Disclosures A. Mahapatra: None. A. Witek: None. G. Toth: None.
Source: Journal of NeuroInterventional Surgery - July 26, 2021 Category: Neurosurgery Authors: Mahapatra, A., Witek, A., Toth, G. Tags: Electronic poster abstracts Source Type: research

E-005 Preliminary results of the SUMMIT NZ ischemic stroke trial: MonoPoint(R) embolectomy featuring a novel 088 aspiration catheter and specialized delivery catheter
ConclusionsPreliminary findings suggest that first-line aspiration embolectomy using a novel MonoPoint® system including an 0.088" inner diameter aspiration catheter achieves a high rate of arterial revascularization with an acceptable safety profile. A full report on enrollment and results are to be presented.Disclosures S. Brew: 1; C; Route 92 Medical. 2; C; Route 92 Medical, Microvention. B. McGuinness: 1; C; Route 92 Medical. 2; C; Route 92 Medical. J. Caldwell: 1; C; Route 92 Medical. 2; C; Route 92 Medical. S. Lee: 1; C; Route 92 Medical. P. Barber: None. A. Holden: 2; C; Medtronic, Gore, Boston Scientific. T. Wu...
Source: Journal of NeuroInterventional Surgery - July 26, 2021 Category: Neurosurgery Authors: Brew, S., McGuinness, B., Caldwell, J., Lee, S., Barber, P., Holden, A., Wu, T., Krauss, M., Laing, A., Collecutt, W., Liebeskind, D., Hetts, S. Tags: Electronic poster abstracts Source Type: research

E-043 Assessing safety of femoral arterial sheath removal in under 24 hours post-intravascular thrombolysis in stroke patients who undergo mechanical thrombectomy
ConclusionSimilar rates of complications were discovered in both groups of patients, without any significant increase in those whose FAS was removed within 24 hours of tPA administration. Further evaluation should be considered to assess the safety of FAS removal in these patients.Disclosures M. Cohen: None. A. Garg: None.
Source: Journal of NeuroInterventional Surgery - July 26, 2021 Category: Neurosurgery Authors: Cohen, M., Garg, A. Tags: Electronic poster abstracts Source Type: research

E-073 Clot bank collaborative registry protocol: Novel method for evaluating ischemic thrombus
ConclusionWe have developed a novel tissue banking protocol to preserve microbiota from arterial thrombi retrieved from ischemic stroke patients. While there is no consensus which class of pathogens is implicated in the susceptibility to stroke, multiple studies including our own, have shown bacterial fragments and communities in cerebral thrombi. The specimens captured during standard-of-care thrombectomy allow us to characterize and functionally define the microbiota associated with cerebral thrombi in ischemic stroke patients.Disclosures M. Walker: 2; C; Medtronic. A. Edlund: None. C. Dupont: None. G. Tan: None. C. Kell...
Source: Journal of NeuroInterventional Surgery - July 26, 2021 Category: Neurosurgery Authors: Walker, M., Edlund, A., Dupont, C., Tan, G., Kelly, C., Levy, S., Federico, E., Levitt, M. Tags: Electronic poster abstracts Source Type: research

E-083 Safety and efficacy of xact stent in tandem internal carotid artery and intracranial large vessel occlusion
ConclusionsThe Xact carotid stent is safe and efficacious in the treatment of tandem ICA/ICAO lesions. Larger prospective trials are needed to help confirm our retrospective findings.Disclosures M. Oliver: None. G. Dawod: None. S. Zaidi: None. M. Jumaa: None.
Source: Journal of NeuroInterventional Surgery - July 26, 2021 Category: Neurosurgery Authors: Oliver, M., Dawod, G., Zaidi, S., Jumaa, M. Tags: Electronic poster abstracts Source Type: research