Zimmer, Inc. - CPT Hip System - Class 2 Recall
CPT Hip System, Parts 00-8114-002-10 and 00-8011-004-00 Hip joint metal/polymer semi-constrained cemented prosthesis. The CPT Hip System is indicated for cemented use in: Patients suffering from severe hip pain and disability due to rheumatoid arthritis, osteoarthritis, traumatic arthritis, polyarthritis, collagen disorders, avascular necrosis of the femoral head, and nonunion of previous fractures of the femur. Patients with congenital hip dysplasia, protrusio acetabuli, or slipped capital femoral epiphysis. Patients suffering from disability due to previous fusion. Patients with previously failed endoprostheses and/o...
Source: Medical Device Recalls - December 31, 2013 Category: Medical Equipment Source Type: alerts

Zimmer, Inc. - NexGen Complete Knee Solutions Stemmed Tibial Component Precoat - Class 2 Recall
NexGen¿ Complete Knee Solutions Stemmed Tibial Component Precoat NexGen Tibial Baseplates are part of the NexGen systems of semi-constrained, non-linked condylar knee prosthesis. The device is indicated for patients with severe knee pain and disability due to: Rheumatoid arthritis, osteoarthritis, traumatic arthritis, polyarthritis; Collagen disorders, and/or avascular necrosis of the femoral condyle; Post-traumatic loss of joint configuration, particularly when there is patellofemoral erosion, dysfunction or prior patellectomy; Moderate valgus, varus, or flexion deformities. (Source: Medical Device Recalls)
Source: Medical Device Recalls - December 12, 2013 Category: Medical Equipment Source Type: alerts

Zimmer, Inc. - Zimmer Trabecular Metal Total Ankle Tibial Base and Talar Components - Class 2 Recall
Zimmer Trabecular Metal Total Ankle Talar Component Right Sizes 1-6 Total ankle arthroplasty is intended to provide a patient with limited mobility by restoring alignment, reducing pain and preserving the flexion/extension movement within the ankle joint.The Zimmer Trabecular Metal Total Ankle is indicated as a total ankle replacement in primary or revision surgery for patients with: " Rheumatoid arthritis. " Post-traumatic arthritis. " Degenerative arthritis. This device is intended for cemented use only. (Source: Medical Device Recalls)
Source: Medical Device Recalls - December 11, 2013 Category: Medical Equipment Source Type: alerts

Zimmer, Inc. - Zimmer Trabecular Metal Total Ankle Tibial Base and Talar Components - Class 2 Recall
Zimmer Trabecular Metal Total Ankle Tibial Base Component Sizes 1-6 Total ankle arthroplasty is intended to provide a patient with limited mobility by restoring alignment, reducing pain and preserving the flexion/extension movement within the ankle joint.The Zimmer Trabecular Metal Total Ankle is indicated as a total ankle replacement in primary or revision surgery for patients with: " Rheumatoid arthritis. " Post-traumatic arthritis. " Degenerative arthritis. This device is intended for cemented use only. (Source: Medical Device Recalls)
Source: Medical Device Recalls - December 11, 2013 Category: Medical Equipment Source Type: alerts

Zimmer, Inc. - Zimmer Trabecular Metal Total Ankle Tibial Base and Talar Components - Class 2 Recall
Zimmer Trabecular Metal Total Ankle Talar Component Left Sizes 1-6 Total ankle arthroplasty is intended to provide a patient with limited mobility by restoring alignment, reducing pain and preserving the flexion/extension movement within the ankle joint.The Zimmer Trabecular Metal Total Ankle is indicated as a total ankle replacement in primary or revision surgery for patients with: " Rheumatoid arthritis. " Post-traumatic arthritis. " Degenerative arthritis. This device is intended for cemented use only. (Source: Medical Device Recalls)
Source: Medical Device Recalls - December 11, 2013 Category: Medical Equipment Source Type: alerts

Stelkast Co - SC2316, Distal Femoral Augment with Screw - Class 2 Recall
SC2316, Distal Femoral Augment with Screw Total knee replacement due to osteoarthritis, osteonecrosis, rheumatoid arthritis and/or post-traumatic degenerative problems and revision of failed previous reconstructions. (Source: Medical Device Recalls)
Source: Medical Device Recalls - September 4, 2013 Category: Medical Equipment Source Type: alerts

Integra LifeSciences Corp. - Ascension Orthopedics Carpal/Metacarpal (CMC) Saddle - Class 3 Recall
CMC Saddle Product Usage: The Ascension CMC is intended to resurface the proximal end of the first metacarpal in cases of rheumatoid arthritis, traumatic arthritis, osteo-arthritis, or post-fracture deformation or bone loss which present as either a painful, unstable thumb, or a thumb with limited range of motion. This is an uncemented prosthesis designed for press fit use only. (Source: Medical Device Recalls)
Source: Medical Device Recalls - June 22, 2013 Category: Medical Equipment Source Type: alerts