Sensors, Vol. 22, Pages 3639: The Influence of Air Humidity on the Output Signal from an Ionization Smoke Detector in the Presence of Soot Nanoparticles

Sensors, Vol. 22, Pages 3639: The Influence of Air Humidity on the Output Signal from an Ionization Smoke Detector in the Presence of Soot Nanoparticles Sensors doi: 10.3390/s22103639 Authors: Tomasz Jankowski Piotr Sobiech Szymon Jakubiak In 2019, the European Committee for Standardization (CEN) initiated work on the preparation of a strategy for air quality monitoring at workplaces. The aim was to determine the concentrations of nano-objects and their aggregates and agglomerates (NOAA) by means of direct measurements using low-cost sensors. There is a growing need for low-cost devices that can continuously monitor the concentrations of nanoparticles, and that can be installed where nanoparticles are used or created spontaneously. In search of such a device, in this study, a smoke detector with an ionization sensor was tested. The aim of the research was to investigate the response of the analog output signal with respect to changes in environmental parameters such as the relative humidity of air. The research was conducted in controlled laboratory conditions, and the results confirmed that an ionization detector could be used to measure the concentrations of nanoaerosols. The modified smoke detector detected soot particles smaller than 100 nm. The linear regression line was calculated for the relative humidity dataset and had a slope coefficient of −1.214 × 10−4; thus, the value of the output signal was constant during t...