IJERPH, Vol. 19, Pages 3581: Reliability of Tooth Width Measurements Delivered by the Clin-Check Pro 6.0 Software on Digital Casts: A Cross-Sectional Study
IJERPH, Vol. 19, Pages 3581: Reliability of Tooth Width Measurements Delivered by the Clin-Check Pro 6.0 Software on Digital Casts: A Cross-Sectional Study
International Journal of Environmental Research and Public Health doi: 10.3390/ijerph19063581
Authors:
Milagros Adobes Martin
Erica Lipani
Laura Bernes Martinez
Alfonso Alvarado Lorenzo
Riccardo Aiuto
Daniele Garcovich
The purpose of this study was to assess the accuracy and reliability of tooth width measurements and Bolton Indices delivered by the Clin-Check Pro 6.0 software (Align Technology, San José, CA, USA). Fifty-four plaster casts were selected and measured with a manual calliper by a trained and calibrated observer. The data gathered were compared with those delivered by the software on the corresponding fifty-four virtual casts. The method reliability of the software was assessed by comparing the measurements performed by the software on 201 pairs of clin-checks corresponding to two consecutive treatment phases. Accuracy and reliability were statistically assessed using a mixed model. The software tends to provide larger widths compared with the manual method. Statistically significant differences were found in 23 teeth. At a global level, the mean difference between the methods was −0.19 mm, with a Dahlberg error of 0.24 mm and an intraclass correlation coefficient of 0.98. The Bolton Indices delivered by the two methods had a moderate correlation (ICC = 0.59; 0.69...
Source: International Journal of Environmental Research and Public Health - Category: Environmental Health Authors: Milagros Adobes Martin Erica Lipani Laura Bernes Martinez Alfonso Alvarado Lorenzo Riccardo Aiuto Daniele Garcovich Tags: Article Source Type: research