Plethysmography Variability Index and Stroke Volume Variation Changes in Relation to Central Venous Pressure Changes During Living Related Donor Right Hepatotomy: A Diagnostic Test Accuracy

CONCLUSIONS: Plethysmography variability index and stroke volume variation showed negligible correlation and poor agreement with central venous pressure. Transfusion-free dissection was possible despite normovolemia, with median values of 8 mm Hg central venous pressure, 10% stroke volume variation, and 12% plethysmography variability index. Plethysmography variability index and stroke volume variation were unable to discriminate donors with increased blood loss.PMID:34085912 | DOI:10.6002/ect.2021.0546
Source: Experimental and Clinical Transplantation : official journal of the Middle East Society for Organ Transplantation - Category: Transplant Surgery Authors: Source Type: research