[Comparison of Two Anti-HIV Confirmatory Assays: Recombinant HIV 1/2 Line Immunoassay and Geenius HIV 1/2 Confirmatory Test].

In this study, the supplemental recombinant HIV 1/2 LIA (INNO-LIA®, Fujirebio, Ghent, Belgium) used to confirm and differentiate the diagnosis of HIV-1 and HIV-2 infections, and an immunochromatographic supplemental test (Geenius™ (Bio-Rad Laboratories, Marnes-la-Coquette, France) which can provide faster results were compared. One hundred fifty serum samples sent to Ege University Faculty of Medicine Hospital Medical Virology Laboratory with anti-HIV 1/2 and p24 antigen positive and indeterminant results and three HIV-1 positive external quality control samples were included in the study. Samples were tested both with the Geenius™ HIV 1/2 (Bio-Rad Laboratories, Marnes-la-Coquette, France) and recombinant HIV 1/2 LIA (INNO-LIA®, Fujirebio, Ghent, Belgium). HIV 1 viral load was evaluated by using Abbott real-time HIV-1 test in Abbott m200sp system (Abbott Molecular, Wiesbaden, Germany) in plasma samples. In both assays, the results were consistent in 147 samples (96.08%). Six samples that have discordant results were as follows: one sample was LIA HIV-1 positive and Geenius indeterminate, two samples were LIA indeterminant and Geenius HIV-1 positive, and in three samples, LIA was indeterminate and Geenius negative. In two EIA reactive samples (2/97, 2.06%) and three EIA negative samples (3/53, 5.66%) LIA results were indeterminant. Geenius test, on the other hand, correctly identified HIV positive and negative samples. The immunochromatographic test could be used in the ...
Source: Mikrobiyoloji Bulteni - Category: Microbiology Tags: Mikrobiyol Bul Source Type: research