Effect of baseline test selection on glaucoma progression detection by optical coherence tomography-guided progression analysis.

CONCLUSION: Glaucoma progression detection by OCT-GPA was affected by baseline test selection, especially in eyes with a greater reduction in progression. GCIPL thickness was less influenced by baseline test selection compared to RNFL thickness. PMID: 32586934 [PubMed - as supplied by publisher]
Source: The British Journal of Ophthalmology - Category: Opthalmology Authors: Tags: Br J Ophthalmol Source Type: research