Left bundle branch area pacing is superior to right ventricular septum pacing concerning depolarization ‐repolarization reserve
ConclusionLBBAP proves to be a feasible and safe pacing procedure with better depolarization ‐repolarization reserve, which may predict lower risk of ventricular arrhythmia and sudden cardiac death.This article is protected by copyright. All rights reserved.
Source: Journal of Cardiovascular Electrophysiology - Category: Cardiology Authors: Jingfeng Wang,
Yixiu Liang,
Wei Wang,
Xueying Chen,
Jin Bai,
Haiyan Chen,
Yangang Su,
Ruizhen Chen,
Junbo Ge Tags: DEVICE THERAPY Source Type: research