Thyroid dose ‐volume thresholds for the risk of radiation‐related hypothyroidism in nasopharyngeal carcinoma treated with intensity‐modulated radiotherapy—A single‐institution study

ConclusionWe recommendV25Gy ≤ 60%,V35Gy ≤ 55%, andV45Gy ≤ 45% as the “stringent” DVH line, andV25Gy >  95%,V35Gy >  90%, andV45Gy >  75% as the “inhibition” DVH line, under the precondition of not compromising the target coverage. These findings could help in the design of individual treatment plans and, eventually, to lowering of HT prevalence.
Source: Cancer Medicine - Category: Cancer & Oncology Authors: Tags: ORIGINAL RESEARCH Source Type: research