[Comparison of Plaster Fixation and Kirschner Wire Transfixation as Temporary Fixation of Displaced Ankle Fractures - Randomised Prospective Study].

CONCLUSIONS Plaster fixation or Kirschner wires for temporal fixation of displaced ankle fractures shall be applied on a case by case basis. Based on our findings, the application of plaster fixation to displaced ankle fractures does not provide adequate stability of the reduced fracture and in case of re-displacement the status of soft tissues deteriorates. The impossibility to control the status of soft tissues in plaster fixation and the lower complication rate in fixation with K wires constitute additional reasons why this fixation technique via the sole of the foot appears to reap more benefits. Key words:displaced ankle fractures, temporal fixation, plaster fixation, Kirschner wire transfixation, complications. PMID: 31070574 [PubMed - in process]
Source: Acta Chirurgiae Orthopaedicae et Traumatologiae Cechoslovaca - Category: Orthopaedics Tags: Acta Chir Orthop Traumatol Cech Source Type: research