Sterilization of Human Amniotic Membrane Using an Ozone Hydrodynamic System

Ann Biomed Eng. 2024 Feb 27. doi: 10.1007/s10439-024-03467-3. Online ahead of print.ABSTRACTHuman amniotic membrane (hAM) is an important biomaterial for Tissue Engineering, due to its great regenerative properties and potential use as a scaffold. The most used procedure to sterilize biomaterials is gamma-irradiation, but this method can affect several properties, causing damage to the structure and reducing the growth factors. The present work evaluated the efficiency of a new method based on ozonated dynamic water for hAM sterilization. HAM fragments were experimentally contaminated with Staphylococcus aureus, Escherichia coli, Candida albicans, Staphylococcus epidermidis, and Clostridium sporogenes (106 CFU/mL) and submitted to sterilization process for 5, 10 and 15 min. The analyses did not reveal microbial activity after 10 min for S. aureus and C. sporogenes and after 15 min for E. coli and S. epidermidis. The microbial activity of C. albicans was reduced with the exposure time increase, but the evaluated time was insufficient for complete sterilization. The depyrogenation process was investigated for different ozonation times (15, 20, 25, 30, and 35 min) to evaluate the ozone sterilization potential and presented promising results after 35 min. The ozone effect on hAM structure was evaluated by histological analysis. A decrease in epithelium average thickness was observed with the exposure time increase. Furthermore, some damage in the epithelium was observed when hAM ...
Source: Annals of Biomedical Engineering - Category: Biomedical Engineering Authors: Source Type: research