CT of the Larynx: Is an Additional High-Resolution Acquisition Necessary for Diagnostic Accuracy? [HEAD AND NECK IMAGING]

CONCLUSIONS: Reformatted images from our institution's standard neck CT acquisition were less accurate than dedicated images of the larynx for analysis of laryngeal tumor extension. Focused images of the larynx were needed to optimize interpretation.
Source: American Journal of Neuroradiology - Category: Radiology Authors: Tags: HEAD AND NECK IMAGING Source Type: research