Standards of practice in forensic age estimation with CT of the medial clavicular epiphysis —a systematic review

The objective of this analysis was to assess adherence to AGFAD recommendations among practitioners of FAE and analyse reported dose-relevant CT scan parameters with t he objective of helping to establish evidence-based dose reference values for FAE. A systematic literature search was conducted in PubMed and in Google Scholar with specific MeSH terms to identify original research articles on FAE with CT of the MCE from 1997 to 2022. A total of 48 studies were incl uded. Adherence to AGFAD recommendations among practitioners of FAE is high regarding the use of Schmeling main stages (93%), bone window (79%), ≤ 1 mm CT slices (67%), axial/coronal CT images (65%), and Kellinghaus sub-stages (59%). The reporting of CT technique and CT dose-relevant scan par ameters is heterogeneous and often incomplete in the current literature. Considering the success achieved by the AGFAD in creating standards of practice of FAE in living subjects, there is potential for the AGFAD to establish standards for radiation protection in FAE as well.
Source: International Journal of Legal Medicine - Category: Medical Law Source Type: research