Preliminary Assessment of Reference Region Quantification and Reduced Scanning Times for [ < sup > 18 < /sup > F]SynVesT-1 PET in Parkinson's Disease

The objectives of this work were to evaluate a noninvasive (reference tissue) quantification method for [18F]SynVesT-1 in PD patients and to determine the minimum scan time necessary for accurate quantification. [18F]SynVesT-1 PET scans were acquired in 5 patients with PD and 3 healthy control subjects for 120 min with arterial blood sampling. Quantification was performed using the one-tissue compartment model (1TCM) with arterial input function, as well as with the simplified reference tissue model (SRTM) to estimate binding potential (BPND) using centrum semiovale (CS) as a reference region. The SRTM2 method was used with k2' fixed to either a sample average value (0.037 min-1) or a value estimated first through coupled fitting across regions for each participant. Direct SRTM estimation and the Logan reference region graphical method were also evaluated. There were no significant group differences in CS volume, radiotracer uptake, or efflux (ps > 0.47). Each fitting method produced BPND estimates in close agreement with those derived from the 1TCM (subject R2s > 0.98, bias < 10%), with no difference in bias between the control and PD groups. With SRTM2, BPND estimates from truncated scan data as short as 80 min produced values in excellent agreement with the data from the full 120 min scans (bias < 6%). While these are preliminary results from a small sample of patients with PD (n = 5), this work suggests that accurate synaptic density quantification may be perf...