Impact of stenosis resistance and coronary flow capacity on fractional flow reserve and instantaneous wave-free ratio discordance: a  combined analysis of DEFINE-FLOW and IDEAL

CONCLUSIONS: Discordance with FFR+/iFR- is characterised by maximal flow values, CFR, and CFC patterns similar to FFR-/iFR- concordance that justifies conservative therapy. Discordance with FFR-/iFR+ on the other hand, is characterised by low flow values, CFR, and CFC patterns similar to iFR+/FFR+ concordance that may benefit from percutaneous coronary intervention.PMID:37594612 | DOI:10.1007/s12471-023-01796-x
Source: Netherlands Heart Journal - Category: Cardiology Authors: Source Type: research