Incomplete resection of colorectal polyps of 4 –20 mm in size when using a cold snare, and its associated factors
Conclusions CSP for polyps of 4–9 mm is safe and feasible; however, for lesions ≥ 10 mm, CSP failure occurs frequently, and the IRR remains high even after technical success. Incomplete resection was associated with flat polyps, visual residual polyp, piecemeal resection, and difficult polypectomies. [...] Georg Thieme Verlag KG Rüdigerstraße 14, 70469 Stuttgart, GermanyArticle in Thieme eJournals: Table of contents | Abstract | Full text
Source: Endoscopy - Category: Gastroenterology Authors: von Renteln, Daniel Djinbachian, Roupen Benard, Florence Barkun, Alan N. Bouin, Mickael Bouchard, Simon Deslandres, Érik Panzini, Benoit Sidani, Sacha Leduc, Raymond Jobse, Bruce C. Pohl, Heiko Tags: Original article Source Type: research