Customized Citrate Anticoagulation versus No Anticoagulant in Continuous Venovenous Hemofiltration in Critically Ill Patients with Acute Kidney Injury: A Prospective Randomized Controlled Trial

Conclusion: Customized citrate-based replacement solution improved filter survival in CVVH compared to anticoagulant-free strategy. This regimen is safe, feasible, and suitable for low- to middle-income countries.Blood Purif
Source: Blood Purification - Category: Hematology Source Type: research