Effect of Collagenase A on Descemet Membrane Endothelial Keratoplasty Scroll Tightness

Purpose: The scrolling properties of the Descemet membrane endothelial keratoplasty (DMEK) graft are essential for surgical success. Currently, there is limited knowledge on what dictates the tightness of the DMEK scroll. The purpose of this study was to determine the impact of temperature and protein digestion on DMEK graft scroll tightness. Methods: For the temperature experiment, a total of 28 eyes were used for this study. Scrolls in the cold group were kept at 4°C while scrolls in the hot group were kept at 37°C. Scroll width was recorded at the 5-, 15-, and 30-minute mark. For the protein digestion experiment, a total of 18 eyes were exposed to collagenase A (10 CDU/mL) in Optisol solution. Scroll width was recorded at the time points of 1, 3, 5, 10, and 20 minutes. Results: The results of the temperature experiment did not yield any statistically significant changes in the mean scroll width of the DMEK scrolls across both temperature ranges and observation times. For the protein digestion experiment, the mean scroll width grew from 1.85 mm to 2.13 mm from the beginning of the experiment until the final observation at 20 minutes. This is a 14.7% change over 20 minutes with a P value (
Source: Cornea - Category: Opthalmology Tags: Basic Investigation Source Type: research