Tri- and bi-exponential diffusion analyses of the kidney: effect of respiratory-controlled acquisition on diffusion parameters
This study examined whether respiratory-controlled acquisition influences diffusion parameters obtained with intravoxel incoherent motion (IVIM) analysis using tri-exponential and bi-exponential models. Ten healthy volunteers were examined on a 3.0  T MRI system to obtain coronal diffusion-weighted images of both kidneys. The participants were scanned twice using respiratory-triggering (RT) and free-breathing (FB) acquisition to assess the repeatability of the measurements. We determined mean signal intensities in the renal cortex at eachbvalue. Then, perfusion-related diffusion coefficient (Dp), fast-free diffusion coeff...
Source: Radiological Physics and Technology - July 31, 2023 Category: Physics Source Type: research

Method for measuring noise-power spectrum independent of the effect of extracting the region of interest from a noise image
This study aimed to evaluate the impact of region of interest (ROI) size on noise-power spectrum (NPS) measurement in computed tomography (CT) images and to propose a novel method for measuring NPS independent of ROI size. The NPS was measured using the conventional method with an ROI of sizeP × P pixels in a uniform region in the CT image; the NPS is referred to as NPSR=P. NPSsR=256, 128, 64, 32, 16, and 8 were obtained and compared to assess their dependency on ROI size. In the proposed method, the true NPS was numerically modeled as an NPSmodel, with adjustable parameters, and a noise image with the property of the...
Source: Radiological Physics and Technology - July 29, 2023 Category: Physics Source Type: research

New patient setup procedure using surface-guided imaging to reduce body touch and skin marks in whole-breast irradiation during the COVID-19 pandemic
This study aimed to assess the effectiveness of a new patient-setup procedure using surface-guided imaging during the coronavirus disease 2019 (COVID-19) pandemic for left-sided whole-breast irradiation with deep inspiration breath-hold. Two setup procedures were compared regarding patient positioning accuracy for the first 22 patients. The first was a traditional setup (T-setup) procedure that used a surface-guided system after patient setup with traditional skin marks and lasers. The second procedure involved a new setup (N-setup) that used only a surface-guided system. The positioning accuracy of the remaining 23 patien...
Source: Radiological Physics and Technology - July 20, 2023 Category: Physics Source Type: research

Deep learning model for predicting the presence of stromal invasion of breast cancer on digital breast tomosynthesis
AbstractTo develop a deep learning (DL)-based algorithm to predict the presence of stromal invasion in breast cancer using digital breast tomosynthesis (DBT). Our institutional review board approved this retrospective study and waived the requirement for informed consent from the patients. Initially, 499 patients (mean age 50.5  years, age range, 29–90 years) who were referred to our hospital under the suspicion of breast cancer and who underwent DBT between March 1 and August 31, 2019, were enrolled in this study. Among the 499 patients, 140 who underwent surgery after being diagnosed with breast cancer were selected ...
Source: Radiological Physics and Technology - July 19, 2023 Category: Physics Source Type: research

Correction: Dr. Kunio Doi is awarded the 23rd Gray Medal by the ICRU
(Source: Radiological Physics and Technology)
Source: Radiological Physics and Technology - July 19, 2023 Category: Physics Source Type: research

Deep learning model for predicting the presence of stromal invasion of breast cancer on digital breast tomosynthesis
AbstractTo develop a deep learning (DL)-based algorithm to predict the presence of stromal invasion in breast cancer using digital breast tomosynthesis (DBT). Our institutional review board approved this retrospective study and waived the requirement for informed consent from the patients. Initially, 499 patients (mean age 50.5  years, age range, 29–90 years) who were referred to our hospital under the suspicion of breast cancer and who underwent DBT between March 1 and August 31, 2019, were enrolled in this study. Among the 499 patients, 140 who underwent surgery after being diagnosed with breast cancer were selected ...
Source: Radiological Physics and Technology - July 19, 2023 Category: Physics Source Type: research

Correction: Dr. Kunio Doi is awarded the 23rd Gray Medal by the ICRU
(Source: Radiological Physics and Technology)
Source: Radiological Physics and Technology - July 19, 2023 Category: Physics Source Type: research

Compressed sensing reconstruction shortens the acquisition time for myocardial perfusion imaging: a simulation study
AbstractCompressed sensing (CS) has been used to improve image quality in single-photon emission tomography (SPECT) imaging. However, the effects of CS on image quality parameters in myocardial perfusion imaging (MPI) have not been investigated in detail. This preliminary study aimed to compare the performance of CS-iterative reconstruction (CS-IR) with filtered back-projection (FBP) and maximum likelihood expectation maximization (ML-EM) on their ability to reduce the acquisition time of MPI. A digital phantom that mimicked the left ventricular myocardium was created. Projection images with 120 and 30 directions (360 °),...
Source: Radiological Physics and Technology - June 29, 2023 Category: Physics Source Type: research

Impact of list-mode reconstruction and image-space point spread function correction on PET image contrast and quantitative value using SiPM-based PET/CT system
AbstractWe evaluate the effects of list-mode reconstruction and the image-space point spread function (iPSF) on the contrast and quantitative values of positron emission tomography (PET) images using a SiPM-PET/CT system. The evaluation is conducted on an NEMA body phantom and clinical images using a Cartesion Prime SiPM-PET/CT system. The signal-to-background ratio (SBR) of the phantom is set to 2, 4, 6, and 8, and all the PET image data are obtained and reconstructed using 3D-OSEM, time-of-flight, iPSF ( −/ +), and a 4-mm Gaussian filter with several iterations. The evaluation criteria include % background variabilit...
Source: Radiological Physics and Technology - June 27, 2023 Category: Physics Source Type: research