The Inferior, Superior, Temporal Rim Width Pattern (IST Rule) Detects Glaucoma in a Japanese Population

Précis: The inferior>superior>temporal rim width rate (IST pattern) rather than inferior≥superior≥nasal≥temporal (ISNT) pattern was suited for screening glaucoma in Japanese subjects. Failure of the IST pattern was associated with several important risk factors for glaucoma. Purpose: The purpose of this study was to find a rim width rate pattern to yield the highest positive likelihood ratio (LR+) in detecting glaucoma eyes and to identify risk factors for glaucoma correlating with its failure in a population-based setting. Methods: Disc stereophotographs of 2474 eyes of 2474 normal subjects and 237 eyes of 237 glaucoma subjects found in the Kumejima Study were analyzed using computer-assisted planimetry. Among all combinations of the inferior (I), superior (S), nasal (N) and/or temporal (T) rim width rate, a pattern showing the highest LR+ was selected and risk factors for glaucoma correlating with its failure were determined using multiple logistic regression analysis. Results: The average I, S, N, and T rim widths (SD) were 0.45 (0.10), 0.39 (0.09), 0.47 (0.11), and 0.27 (0.07) mm. Among all combinations, the I>S>T rim width rate pattern (IST pattern) disregarding the N rim width showed the highest LR+ of 2.002 (95% confidence interval, 1.778–2.253). Failure of the IST pattern in normal eyes correlated with a smaller disc area (PT rim width pattern, the IST pattern, yielded the highest LR+ in detecting glaucoma in Japanese glaucoma eyes ...
Source: Journal of Glaucoma - Category: Opthalmology Tags: Advances in Glaucoma: Original Studies Source Type: research