The prostate health index and the percentage of [-2]proPSA maintain their diagnostic performance when calculated with total and free PSA from different manufacturers

CONCLUSIONS: In the PSA range between 2 and 10 μg/L, [-2]proPSA derivatives maintain their diagnostic performance in PCa detection when calculated with PSA from Roche and Abbott. This can lead to a broader implementation of these indices in clinical laboratories worldwide.PMID:34318651 | DOI:10.1515/cclm-2021-0554
Source: Clinical Prostate Cancer - Category: Cancer & Oncology Authors: Source Type: research