Rapid changes in serum IL-6 levels in preterm newborns with Gram-negative early-onset sepsis.

Rapid changes in serum IL-6 levels in preterm newborns with Gram-negative early-onset sepsis. Cytokine. 2020 Nov 23;:155371 Authors: Kobayashi T, Iwatani S, Hirata A, Yamamoto M, Yoshimoto S Abstract Early-onset sepsis (EOS) remains a leading cause of morbidity and mortality for newborns, especially in preterm birth. Serum IL-6 levels are used as an accurate marker for EOS; however, no study has focused on the changes in serum IL-6 levels in newborns with EOS. Here, we investigated 6 preterm newborns (23.4-28.2 wks' gestational age) with birthweights of 570-1080 g who were diagnosed with EOS. All newborns received active treatment, including exchange transfusions and/or polymyxin B-immobilized fiber column direct hemoperfusion for septic shock. In the 3 surviving newborns, serum-IL-6 levels peaked at >500,000, 256,500, and 356,000 pg/mL within 12 h of life, and then decreased to <100 pg/mL by 72 h of life. In the 3 newborns who died at 17, 30, and 61 h of life, serum IL-6 levels increased to >500,000, 198,000, and 1,354,000 pg/mL, respectively, prior to death. Therefore, in preterm newborns suspected of EOS, serial serum IL-6 determinations would be useful for not only detecting EOS, but also for monitoring sepsis severity. PMID: 33243627 [PubMed - as supplied by publisher]
Source: Cytokine - Category: Molecular Biology Authors: Tags: Cytokine Source Type: research