Ventilator dyssynchrony & #8211; Detection, pathophysiology, and clinical relevance: A Narrative review

Peter D Sottile, David Albers, Bradford J Smith, Marc M MossAnnals of Thoracic Medicine 2020 15(4):190-198 Mortality associated with the acute respiratory distress syndrome remains unacceptably high due in part to ventilator-induced lung injury (VILI). Ventilator dyssynchrony is defined as the inappropriate timing and delivery of a mechanical breath in response to patient effort and may cause VILI. Such deleterious patient–ventilator interactions have recently been termed patient self-inflicted lung injury. This narrative review outlines the detection and frequency of several different types of ventilator dyssynchrony, delineates the different mechanisms by which ventilator dyssynchrony may propagate VILI, and reviews the potential clinical impact of ventilator dyssynchrony. Until recently, identifying ventilator dyssynchrony required the manual interpretation of ventilator pressure and flow waveforms. However, computerized interpretation of ventilator waive forms can detect ventilator dyssynchrony with an area under the receiver operating curve of >0.80. Using such algorithms, ventilator dyssynchrony occurs in 3%–34% of all breaths, depending on the patient population. Moreover, two types of ventilator dyssynchrony, double-triggered and flow-limited breaths, are associated with the more frequent delivery of large tidal volumes >10 mL/kg when compared with synchronous breaths (54% [95&#37...
Source: Annals of Thoracic Medicine - Category: Respiratory Medicine Authors: Source Type: research