Comparison between computerized tomography-guided bronchial width measurement versus conventional method for selection of adequate double lumen tube size.

Conclusion: CT-measured bronchial width predicts the appropriate DLT size better than conventional method. In the absence of CT scan facility, patient height, age, and chest X-ray TW may be used to predict DLT size with reasonable accuracy. PMID: 31621669 [PubMed - in process]
Source: Annals of Cardiac Anaesthesia - Category: Anesthesiology Authors: Tags: Ann Card Anaesth Source Type: research