Development, Validation and Pilot Field Deployment of a Custom Mouthpiece for Head Impact Measurement.

The objective of this study was to develop a mouthpiece sensor with improved head kinematic measurement for use in non-helmeted and helmeted sports through laboratory validation and pilot field deployment in female youth soccer. For laboratory validation, data from the mouthpiece sensor was compared to standard sensors mounted in a headform at the center of gravity as the headform was struck with a swinging pendulum. Linear regression between peak kinematics measured from the mouthpiece and headform showed strong correlation, with r2 values of 0.95 (slope = 1.02) for linear acceleration, 1.00 (slope = 1.00) for angular velocity, and 0.97 (slope = 0.96) for angular acceleration. In field deployment, mouthpiece data were collected from four female youth soccer players and time-synchronized with film. Film-verified events (n = 915) were observed over 9 practices and 5 games, and 632 were matched to a corresponding mouthpiece event. This resulted in an overall sensitivity of 69.2% and a positive predictive value of 80.3%. This validation and pilot field deployment data demonstrates that the mouthpiece provides highly accurate measurement of on-field head impact data that can be used to further study the effects of impact exposure in both helmeted and non-helmeted sports. PMID: 31297724 [PubMed - as supplied by publisher]
Source: Annals of Biomedical Engineering - Category: Biomedical Engineering Authors: Tags: Ann Biomed Eng Source Type: research