Performance of Bio-Rad Geenius HIV-1/2 Confirmatory Assay in HIV-1, HIV-2 and HIV-1/2 dually reactive patients - comparison with INNO-LIA and Immunocomb discriminatory assays.
CONCLUSIONS: Geenius has similar performance characteristics as INNO-LIA, and performs considerably better than Immunocomb, for differentiating between HIV-types. This is especially true when using the Geenius reader while manual reading of the Geenius assay seemed to overestimate the numbers of HIV-1/2 dually reactive samples.
PMID: 30871983 [PubMed - as supplied by publisher]
Source: Journal of Virological Methods - Category: Virology Authors: Lindman J, Langhoff Hønge B, Kjerulff B, Medina C, da Silva ZJ, Erikstrup C, Norrgren H, Månsson F, for Bissau HIV Cohort Study Group, SWEGUB CORE Group Tags: J Virol Methods Source Type: research