Validation of a Parametric Finite Element Human Femur Model.

Conclusions Impactor forces from simulations, on average, matched experimental values at the time of failure. In addition, the simulations were able to match the trends in the experimental dataset. PMID: 28095035 [PubMed - as supplied by publisher]